4.1.1 Rear Panel Connections
1
24V DC connector
2.1mm DC jack (centre pin positive).
2
RJ45 connector
For connection back to the A 4595A. Either port can be used
3
DIP switch options
These switches set the chime options and also assign a location number or ID to the console.
4
Chime volume
Use this volume to adjust the chime level.
5
Microphone volume
Use this volume to adjust the microphone level.
4.1.2 DIP Switch Settings
A series of DIP switches which are accessed on
the rear of the unit provide a number of options.
DIP switch 1 sets the PA system chime on or off.
DIP switch 2 sets the internal chime on or off.
DIP switches 3-4 select the ID number for the console.
Fig 4.1b shows the ID settings.
A maximum number of 4 consoles can be connected to the A 4595A.
Ensure power is switched off when adjusting DIP switches.
New settings will be effective when power is switched back on.
18
Redback® Proudly Made In Australia
DIP Switches 1-3 Settings
SW
On
O
1
PA System Chime On
PA System Chime O
2
Internal Chime On
Internal Chime O
24VDC In
1
2
IMPORTANT NOTE:
Mic
Chime
Volume
Volume
Switches 3-4
Set the
Console ID
ON
4
3
ID
O
O
1
O
On
2
1 2 3 4
On O
3
On On
4
1 2 3 4
3
4
DIP Switches 1-3 Settings
On
SW
1
PA System Chime On
2
Internal Chime On
Fig 4.1a
5
O
PA System Chime O
Internal Chime O
Switches 3-4
Set the
Console ID
4
3
O
O
O
On
On O
On On
Fig 4.1b