Redback A 4595A Operating Manual page 11

School lockdown controller
Table of Contents

Advertisement

Lock In 24V Out:
These contacts are for switched 24V outputs whenever the LockIn mode is activated. These may be used to run external
systems such as strobes in unusually noisy environments or for hearing impaired students or staff. They may also be used
for the connection of override relays in remote volume controls.
Lock Out 24V Out:
These contacts are for switched 24V outputs whenever the LockIn mode is activated. These may be used to run external
systems such as strobes in unusually noisy environments or for hearing impaired students or staff. They may also be used
for the connection of override relays in remote volume controls.
All Clear 24V Out:
These contacts are for switched 24V outputs whenever the All Clear mode is activated. These may be used to run external
systems such as strobes in unusually noisy environments or for hearing impaired students or staff. They may also be used
for the connection of override relays in remote volume controls.
Common 24V Out:
These contacts are for switched 24V outputs whenever any Bell, Pre-Bell, Standby, Lock In, Lock Out, All Clear, Fire Test,
Aux MP3-1, Aux MP3-2 or Aux MP3-3 tones are activated or when paging is active. These may be used to run external
systems such as strobes in unusually noisy environments or for hearing impaired students or staff. They may also be used
for the connection of override relays in remote volume controls.
Emergency 24V Out:
These contacts are for switched 24V outputs whenever the Standby, Lock In, Lock Out, Fire Test, Fire Alarm and All Clear
modes are activated or when emergency paging is active. These may be used to run external systems such as strobes in
unusually noisy
environments or for hearing impaired students or staff. They may also be used for the connection of override relays in
remote volume controls.
A possible use for this output would be to override the zone which provides audio to the school assembly area. General
paging is blocked to this area but emergency paging is still required.
24VDC
24VDC
Interface
Input
Backup
Micro
SD Card
(Firmware
updates)
+ _
-
+
DIP Switch Settings
IMPORTANT NOTE
SW
On
O
Ensure power is switched o when
1
Loop MP3
Play MP3 once
adjusting DIP switches. New
24V DC
24V DC
settings will be e ective when
2-8
Not Used
IN
power is switched back on.
IN
DIP Switches
1
2
3
4
5
6
7
8
+ _
Micro SD Card
-
+
1 2 3 4 5 6 7 8
(16GB Maximum)
www.altronics.com.au
Redback® A 4595A School Lockdown Controller
Manufactured in Australia
SW ON
24V DC Switched Out
By Altronic Distributors Pty. Ltd.
1
(Outputs limited to 120mA)
2
3
4
3
2
1
4
5-7
8
_
_
_
_
+
+
+
+
4
3
2
1
All Clear
Lock In
Standby
Contacts
24V Out
24V Out
24V Out
All switched outputs limited to 120mA maximum current draw
External
+24V
24V DC Supply
GND
(eg school bell, lunch bell etc)
DIP Switch Settings
Not Used
Station Edit Lockout Enabled
Edit Time Lockout Enabled
A 1709
Clear Memory Lockout Enabled
Not Used
Battery Backup On
50 EVENT TIMER
1
2
3
4
5
6
7
8
DIP Switches
Lock Out
Bell/Pre-Bell
Common
Emergency
24V Out
24V Out
24V Out
24V Out
Interface 1
Interface 2
+24V
GND
N/C1
COM1
N/O1
N/C2
COM2
N/O2
24V Relay Board
(Altronics S 4444)
24V Bell
Fig 3.3
Redback® Proudly Made In Australia 11
1
2
1
2
L
R
3
4
3
4
Mp3
Master
Audio
To Wall Plates
To Paging Consoles
Volume
Volume
Out
Made in Australia by
Altronic Distributors
Pty Ltd
www.redbackaudio.com.au