Other Options - United Technologies Carrier 30RQM 160 Installation, Operation And Maintenance Instructions

Reversible air-to-water heat pump
Table of Contents

Advertisement

10 - OPTIONS

10.8 - Other options

Options
Corrosion protection,
traditional coils
Low-temperature brine
solution
Unit equipped for air 
discharge ducting
Low noise level
Very low noise level
IP54 control box
Protection grilles 
Enclosure panels
Soft Starter
Winter operation down to 
-20°C
Water exchanger frost 
protection
Exchanger & hydraulic  frost 
protection
Partial heat recovery
Master/slave operation
Compressor discharge valves
HP single-pump hydraulic 
module
HP dual-pump hydraulic 
module
LP single-pump hydraulic 
module
LP dual-pump hydraulic 
module
HP variable-speed single-
pump hydraulic mod.
HP variable-speed dual-pump 
hydraulic mod.
Lon gateway
54
No.
Description
Fins made of pre-treated aluminium 
3A
(polyurethane and epoxy)
Low temperature chilled water production 
6B
down to -8°C with ethylene or propylene glycol
Unit equipped with high static variable-speed 
fans (maximum 200 Pa), each fan equipped 
12
with a connection flange allowing the 
connection to the ducting system.
Aesthetic and sound absorbing compressor 
15
enclosure
Aesthetic and sound absorbing compressor 
15LS
enclosure associated with low-speed fans
20A Increased leak tightness of electrical box
23
Metallic protection grilles 
23A Side enclosure panels at each end of the coil
25
Electronic starter on each compressor
Fan speed control of lead fan for each circuit 
28
using a variable frequency drive
Electric heater on the water exchanger and the 
41
water piping
42A Electric heater on the water exchanger 
hydronic module and optional expansion tank
Partial heat recovery by desuperheating of the 
49
compressor discharge gas.
Unit equipped with supplementary water outlet 
temperature sensor kit to be field-installed 
58
allowing master/slave operation of two units 
connected in parallel
Shut-off valve on the compressor discharge 
93A
piping
Single high-pressure water pump, water filter, 
electronic water flow control, pressure 
116R
transducers. See hydraulic module option 
chapter
Dual high-pressure water pump, water filter, 
electronic water flow control, pressure 
116S
transducers. See hydraulic module option 
chapter
Single low-pressure water pump, water filter, 
electronic water flow control, pressure 
116T
transducers. See hydraulic module option 
chapter
Dual low-pressure water pump, water filter, 
electronic water flow control, pressure 
116U
transducers. See hydraulic module option 
chapter
Single high-pressure water pump with variable
speed drive (VSD), water filter,  electronic 
116V
water flow control, pressure transducers. 
Multiple possibilities of water flow control. See 
hydraulic module option chapter
Dual high-pressure water pump with variable 
speed drive (VSD), water filter, electronic flow 
116W
switch, pressure transducers. Multiple 
possibilities of water flow control. See hydraulic 
module option chapter
Two-directional communication board 
148D
complying with Lon Talk protocol
Advantages
Improved corrosion resistance, 
recommended for moderate marine and 
urban environments
Covers specific applications such as ice 
storage and industrial processes
Ducted fan discharge, optimised 
condensing or evaporating temperature 
control, based on the operating conditions 
and system characteristics
Noise level reduction by 1 to 2 dB(A)
Noise level reduction for sensible site
Protects the inside of the electrical box 
from dusts and sand. In general this option 
is recommended for installations in 
polluted environments
Coil protection against possible shocks
Improves aesthetics, coil and piping 
protection against impacts.
Reduced start-up current
Stable unit operation for outside air 
temperature from 0°C down to -20°C in 
cooling mode
Water exchanger module frost protection 
between 0°C and -20°C outside air 
temperature
Water exchanger and hydraulic module 
frost protection between 0°C and -20°C 
outside air temperature
Free high-temperature hot-water
production simultaneously with chilled and 
hot-water production
Optimised operation of two heat-pumps 
connected in parallel with operating time 
equalisation
Simplified maintenance
Easy and fast installation (plug & play)
Easy and fast installation (plug & play)
Easy and fast installation (plug & play)
Easy and fast installation (plug & play)
Easy and fast installation (plug & play), 
significant pumping energy cost savings 
(more than two-thirds), tighter water flow 
control, improved sytem reliability
Easy and fast installation (plug & play), 
significant pumping energy cost savings 
(more than two-thirds), tighter water flow 
control, improved sytem reliability
Connects the unit by communication bus to
a building management system 
Use
30RQM/30RQP 
160-520
30RQP
180-230-270-
310
30RQP 160-520
30RQM/30RQP 
160-520
30RQP 160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM 160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520
30RQM/30RQP 
160-520