4 Installer Settings

The Installer Settings must be properly configured in order for this thermostat to operate correctly. The
INSTRUCTIONS
Installer Settings are menu driven. The portion of these settings that do not apply to your setup will be
skipped. These settings are indicated below with comments. More detail on each setting follows this table.
1. Press and hold down the
buttons for 3 seconds.
2. Release both buttons and the first
installer setting will be displayed.
3. Change settings as required using the
or
portion of the SpeedBar
NEXT
4. Press
(HOLD) or
move to the next or previous setting,
press
RETURN
to exit.
BACK
DAY/TIME
No. Installer Setting
(
Notes follow this table)
1
Residential or
or Commercial Profile
2
Programming Mode
[note 1]
3
Clock Format
4
Temperature Scale
5
Auto Changeover
6
System Type
7
1st Stage Differential
8
2nd Stage Differential
[note 2]
RETURN
and
.
®
BACK
(PROG) to
NEXT
Factory
Setting
Default
Options
RES
RES
COMM
7 PROG
7 PROG
52 PROG
NO PROG
12 HR
12 HR
24 HR
F DEG
F DEG
C DEG
oF AUTO
oF AUTO
ON AUTO
11CONV
11CONV
11HP
21 HP
1HD
11HD
0.5 DIF1
0.5, 1.0 or
2.0 DIF1
2.0 DIF2
1.0, 2.0, 3.0,
4.0, 5.0 or
6.0 DIF2
INSTRUCTIONS
BACK
DAY/TIME
HUMIDITY
Comments
(More information follows this table)
Select for Residential profile
Select for Commercial profile
Select for 7 day programming mode
Select for 5-2 day programming mode
Select for non-programmable mode
Select for 12 hour clock
Select for 24 hour clock
Select for Fahrenheit display
Select for Celsius display
Disables Auto Changeover mode
Enables Auto Changeover mode
Select for 1H/1C Conventional system
Select for 1H/1C Heat Pump system
Select for 2H/1C Heat Pump system
Select for Heat Only Hydronic system
Select for Hydronic Heat/1C system
Select a 1st stage temperature differential of
.5°, 1° or 2° F (0.2°, 0.5° or 1.0° C)
Select a 2nd stage temperature differential of
1°, 2°, 3°, 4°, 5° or 6° F (0.5°, 1.0°, 1.5°, 2.0°,
2.5° or 3.0° C)
9