DHCP Status
Temperature
Fan State
Battery Status
Overloaded Count Provides a count of the number of times the box has entered the
CPLD version
Boot Revision
Code Revision
Release Revision
CPU Utilization%
Power Supply
Voltage

Status: Network Status

Status: Network Status > Codec
This menu allows the user to view various network-level conditions.
VBrick MPEG-2 Appliance Admin Guide
Dynamic Host Configuration Protocol – Ethernet models only.
Enabled/Disabled. Possible DHCP Status values:
• Disabled
• Succeeded
• Failed
• Succeeded without Subnet Value – No subnet value given;
generated from IP address.
• Succeeded with Invalid Subnet Value – Invalid subnet value given;
generated from IP address.
• Failed over Backplane – Device number invalid in backplane.
• Failed, Invalid Device Unit – Network interface device number
invalid.
• Failed Invalid Cookie – Network interface inoperable.
• Failed, Bind Failed – DHCP server not available or appliance not
connected to network.
• Failed, Out of Memory – Appliance is out of memory. Indicates a
severe condition.
• Failed, Parameter Get Failed – Couldn't retrieve a DHCP
parameter needed/requested.
• Failed, Invalid Boot File – Invalid boot file specified. Indicates a
severe condition.
• Failed, Invalid Retrieved IP address assigned by the server is not a
valid unicast address.
Displays the temperature of the appliance (Celsius).
Displays the state of the fan as
OK or Failed.
Overloaded state.
Displays the Main Board programmable device version number.
Displays the date of the last boot revision.
Displays the date of the last code revision.
Displays the release version number.
The percentage of the Central Processor in use at this time.
Displays the measured voltages present and provided to the VBrick
(24V, 12V, 5V, 3.3V 2.5V). The tolerance range for 24V is minimum
18V to maximum 25V. The range for all other voltages is plus or
minus 5%.
,
or
Not Operational
High

Status

.
Low
63