Number Event Description
22
The 2.5 volts power supply failure has cleared.
23
There is a Real Time Clock battery failure.
24
The unit has been configured to transmit and/or receive video streams beyond
its capability.
25
Signifies the overloaded unit is recovered to normal.
26
A component on the main board failed Power On Self Test (POST).
27
The encoder card in Slot1 failed Power On Self Test (POST).
28
The encoder card in Slot1 failed Power On Self Test (POST).
Configuration: System > Security
Note If you disable Telnet, FTP, IWS, and SNMP, the only way to manage (and re-enable)
these parameters is to connect a PC to the VBrick with a serial cable and use the
Command Line Interface (CLI). You should never disable all the network management
interfaces if you are using COM2 for serial passthrough.
External Telnet
Server
External FTP Server
External IWS
VBrick MPEG-2 Appliance Admin Guide
Default = Enabled. Disabled will prevent Telnet sessions to the
server.
Default = Enabled. Disabled will prevent FTP sessions to the
server including downloading to the VBrick. Note that this feature
must be enabled to upgrade the appliance firmware using
VBDownload.
Default = Enabled. Disabled will prevent you from managing the
VBrick from a web browser using the IWS application.
MPEG-2 Configuration