Configuration: Passthrough > Com2; Configuration: System; Configuration: System > General - VBrick Systems VB4000 Admin Manual

Network video appliances
Hide thumbs Also See for VB4000:
Table of Contents

Advertisement

Baud Rate
Stop Bits
Parity
RTS Control
DTR Control
Operational State
Idle Time out
COM Interface
Type
Dedicated Address Mode
When the Passthrough State is set as Initiator and the Destination is Dedicated, the VBrick
appliance can be configured and identified using either an IP address or Host Name.
Configuration: Passthrough > COM2
Passthrough settings for COM2 are a subset of COM1. See Configuration: Passthrough >
COM1 for complete details. As noted, DTR and RTS are not available for COM2. Under no
conditions are RTS or DTR controls passed through end-to-end. All control handling is
local.

Configuration: System

This menu allows the user to set-system related parameters.
Configuration: System > General
42
Rate of Passthrough port. Rate can be set to the following (Default =
9600): 110, 300, 600, 1200, 2400, 3600, 4800, 7200, 9600, 14400,
19200, 28800, 38400, 57600, 115200.
Number of stop bits for Passthrough port (1 or 2).
None, Even, Odd.
Force Off, Force On or Automatic. If automatic, the control will be
on when Passthrough is active. DTR and RTS are not available for
COM2. Under no conditions are RTS or DTR controls passed
through end-to-end. All control handling is local. DTR and RTS are
not available for COM2.
Force Off, Force On or Automatic. If automatic, the control will be
On when Passthrough is active. Not available on COM2. See note
above.
Describes the current status of a Passthrough connection, including
error conditions, if any. Refer to the Network Status Section. This will
display
if in Passthrough mode.
Active
5–2000 milliseconds. Default = 500. The interval between characters
at which metadata is inserted into the stream.
Describes the COM interface connector. (RS422/485 options are
displayed only if main board has a Part Number ending in xxx3. See
Status: User Information > Main Board.)
• RS232 – standard RS-232 serial port connector.
• RS422/485 – RS-422/485 4-wire serial port connector.
• RS422/485 (Terminated) – RS-422/485 terminated.
© 2009 VBrick Systems, Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb6000Vb5000Vb4000 seriesVb6000 seriesVb5000 series

Table of Contents