7

Dk6010
-

FlUsh COOlING sysTEM AND ChANGING COOlANT (AJ)

(1) Drain Plug
1. Park the tractor on level ground, stop
the engine and let the engine cool down.
2. to drain coolant, remove the drain
plug from the radiator and turn the
radiator cap to the 1st notch to
release pressure in the radiator.
then, remove the cap completely.
3. After all coolant is drained, fit the
drain plug.
4. use clean, fresh water and anti-
freeze to fill the reservoir tank.
5. follow the cleaner manufacture's
instruction.
TD210-EEC인증용-DK6010H,DK6010C,DK634 34
td2O731A
(1) radiator cap
(a) full
6. install the radiator cap securely.
7. start and idle the engine for few
minutes.
8. stop the engine and let it cool.
9. Drain water and cooling system
cleaner and close drain cock.
then, fill with antifreeze and
water mixture and close radiator
cap securely.
10. run tractor at idle until up to op-
erating temperature.
11. check the coolant level in the
reservoir tank. if the level is low,
add coolant.
Coolant capacity [l (U.s. gal)]
To avoid accidents:
Do not remove the radiator cap
td2O732A
while the coolant is hot. steam
(2) reservoir tank
or scalding liquids released
(B) low
from hot cooling system can
burn you seriously. Cool down
the engine first.
Even though the coolant is
cooled down, turn the cap to
its first stop and then wait un-
til it is depressurized before
removing the cap completely.
7,9 (2,1)