C0400: Exposure Lamp's Failure To Turn On; C0410: Exposure Lamp Turning On At Abnormal Timing - Minolta EP1080 Service Manual

Hide thumbs Also See for EP1080:
Table of Contents

Advertisement

1-5. C0400: Exposure Lamp's failure to turn ON

C0410: Exposure Lamp turning ON at abnormal timing

PWB-A
PU1
Symbol
LA1
CN7
TF2
PWB-A
PWB-H
TF2
PWB-H
PU1
LA1
1139T023AA
T-48
Name
Exposure Lamp
Exposure Lamp Thermal Fuse
Main Control Board
AE Sensor Board
Power Supply Unit
1139C10TAA