Cleaning Of The Upper Pre-Image Transfer; Cleaning Of The Magnet Roller Lower Filter - Minolta EP1080 Service Manual

Hide thumbs Also See for EP1080:
Table of Contents

Advertisement

Cleaning of the Upper Pre-Image Transfer Guide Plate

Cleaning of the Magnet Roller Lower Filter

NOTE
At reinstallation, press the Toner Antispill Mylar up
against the Imaging Unit Housing and the rear side of
the copier (in the directions of the arrows) and press
the Bias Seal up against the Imaging Unit Housing
and the front side of the copier (in the directions of
the arrows).
18. Remove two screws to remove the Upper Pre-Image
Transfer Guide Plate.
19. Using a brush, whisk toner and dust off the surface of
the Upper Pre-Image Transfer Guide Plate.
20. Using a brush, whisk toner and dust off the Magnet
Roller Lower Filter.
(No Magnet Roller Lower Filters are mounted in the
copiers for the U.S.A., Canada, and Europe.)
21. Refit the parts to the Imaging Unit and reinstall the
Imaging Unit to the copier.
22. Charge fresh starter and make the ATDC adjustment.
See p. D-52.