(4) Cleaning of the Upper Fusing Roller

1139D198AA

(5) Cleaning of the Upper Paper Separator Fingers

(6) Cleaning of the Fusing Thermistor

(7) Removal of the Lower Fusing Roller

1. Using a soft cloth dampened with alcohol or silicone
oil, wipe clean the Upper Fusing Roller.
1. Using a soft cloth dampened with alcohol or silicone
oil, wipe clean the Upper Paper Separator Fingers.
1. Remove one screw to remove the Fusing Thermistor.
2. Using a soft cloth dampened with alcohol or silicone
oil, wipe clean the Thermistor.
1. Turning it in the direction of the arrow, remove the
Lower Paper Separator Fingers Unit.
2. Remove the Lower Fusing Roller