Magnet Rack - Adjustment - Braillo 300 S2.1 User Manual

Table of Contents

Advertisement

BRAILLO
B 300 S2.1
l
5.7

Magnet Rack - adjustment

Before placing the magnet rack in the printer, two adjustments must be checked.
The first is the distance between the support list and the pivot arms. This is the travelling distance for
the pivot arm. And it should be adjusted to about 0.8 mm using a feeler gauge. Adjust the nuts on
both ends of the magnet rack.
If the 0.8 mm feeler gauge goes half way in, and the 0.9 mm feeler gauge does not go in at all, consid-
er the adjustment OK.
Make sure that the nuts are tight when you are done!
Adjust with these nuts
0.8 mm feeler gauge
66