R F I D E r r o r s
These errors occur when there is an RFID problem. To correct an RFID error, adjust the Read
or Write powers. If the module fails to initialize, contact Technical Support.
When the printer cannot program an inlay, it prints an overstrike pattern on the label. The
overstrike pattern prevents someone from using a bad RFID label.
Your application developer may use different messages than the ones shown.
For non-RFID printer error messages, see "Error Messages" in Chapter 5.
Error
Description
Code
727
Too many inlays within the programmable range. Make sure the read power is correct
for the selected inlay. If the read power is correct and this error occurs, lower the read
power by one and try again.
729
Invalid TID. Invalid inlay. The chip (inlay) embedded in the RFID supply does not
support serialized TID. Make sure the RFID supply supports serialized TID. This may
also be a bad RFID inlay.
732
No RFID optional hardware installed. A non-RFID printer received a format containing
an RFID Data Field. Send the format to an RFID printer with RFID supplies loaded.
735
Error in the RFID module – hardware, software, or firmware. The RFID module may
need to be replaced or has become disconnected. If this error continues, call Technical
Support. Message will say "reboot", press button; printer reboots.
736
RFID inlay encoding failed. The RFID inlay was found in the RF Field (area inside the
printer where RFID inlay is programmed.), but could not be read or programmed. The
RFID module has an error. This may also be a bad RFID inlay. If this error continues,
call Technical Support.
738
Inlay communication failure. This error can occur when
♦ The printer cannot read the TID field.
♦ Invalid read power.
Call technical support. The start encode position may need to be decreased or
increased. The read power level may also need to be increased by 1.
740
RFID Tag Failure. The RFID module detected a problem during encoding. Call
Technical Support.
741
RFID inlay missing. Inlay not found in RF Field (area inside the printer where RFID
inlay is programmed.) This may be a bad RFID inlay. For continuous 741 messages:
♦ The inlay is moving too fast to encode. Decrease the printer's speed. Try
again.
♦ Make sure the correct read and write values are set for the selected inlay
and try again. Call Technical Support.
744
Inlay locked fail or invalid lock code. The RFID inlay is unable to be programmed,
because the lock code is invalid or it is already locked.