Troubleshooting

Condition: Outputs Will Not Energize
Indicator Status
Power
ON
Fault
ON
In #1
ON or OFF
In #2
ON or OFF
SSI
ON
MUTE
OFF
OUT
OFF
Indicator Status
Power
ON
Fault
ON
In #1
ON
In #2
ON
SSI
ON
MUTE
OFF
OUT
Flashing
Indicator Status
Power
ON
Fault
ON
In #1
Flashing or
OFF
In #2
Flashing or
OFF
SSI
ON
MUTE
OFF
OUT
OFF
P/N 109782 Rev.B
Possible Reason/Solution
Two-Hand Control Input Simulta-
neity Error
- Simultaneity failure (> 500 ms)
with status of input
Possible Reason/Solution
External Device Monitoring (EDM)
error
- Feedback open (Y1/Y2)
Possible Reason/Solution
Two-Hand Control Input Error
-Input invalid (NO/NC within an in-
put did not switch within 100 ms)
- Both channels within an input are
closed (S12/S11/S13 or S22/S21/
S23)
- Both channels within an input are
open (S12/S11/S13 or S22/S21/
S23)
www.bannerengineering.com - tel: 763-544-3164
Condition: Outputs Will Not Energize
Indicator Status
Possible Reason/Solution
Power
ON
Two-Hand Control Input Short Cir-
cuit
Fault
Flashing
In #1
Flashing
- Input #1 is short circuited to Input
#2 (S12/S11/S13 to S22/S21/S23)
In #2
Flashing
SSI
OFF
MUTE
OFF
OUT
OFF
Indicator Status
Possible Reason/Solution
Power
ON
Safety Stop Interface Error
Fault
Flashing
In #1
ON or OFF
- Invalid Input - SSI channels did
not operate concurrently, both
In #2
ON or OFF
must open and then both must re-
SSI
Flashing
close (X3/X4 and X5/X6)
MUTE
OFF
OUT
OFF
Indicator Status
Possible Reason/Solution
Power
ON
Power-Up Error
Fault
Flashing
NOTE: This error is a non-recovera-
ble lockout; the power must be re-
In #1
Flashing or
moved, the Inputs must be deactiva-
OFF
ted (cleared or opened) and then
power reapplied.
In #2
Flashing or
- Two-Hand Control Inputs are ac-
OFF
tive, tied-down, or miswired at pow-
er-up (corresponds to flashing In#1/
SSI
OFF
In#2 LEDs)
MUTE
Flashing or
- M1/M2 Input(s) closed at power-up
OFF
(corresponds to flashing MUTE
LED)