LED Indicators

Two-Hand Control Module AT-..M-11KM provides seven indicator LEDs.
Indicator
Description
ON – Power is connected to terminals A1-A2
OFF – No power or low power to terminals A1-A2, or internal power supply failure
Power (Green)
Flashing (only; no other LEDs are ON) – DIP Switch Fault (see
on page 6)
ON – External fault or configuration fault. The corresponding function LED (see below) will flash to indicate
the area where the fault has been detected. See below or
Fault (Red)
OFF – Normal operation
Flashing (only; no other LEDs are ON other than "power") – Internal Fault. See above for repair.
ON – Touch button (Input #1) is activated
Input #1 (Green)
OFF – Touch button is not activated
Flashing – See
ON – Touch button (Input #2) is activated
Input #2 (Green)
OFF – Touch button is not activated
Flashing – See
ON – SSI inputs are closed (X3/X4 and X5/X6)
Safety Stop Input
OFF – SSI inputs are open
(Green)
Flashing – See
ON – M1/M2 are closed and mute cycle is activated
OFF – M1/M2 are not closed (mute cycle not activated)
Mute (Green)
Flashing – Mute cycle is prevented because of M1/M2 simultaneity error, Mute Lamp error,
Mute Enable not closed before M1/M2 active, power-up with M1/M2 closed,
Backdoor timer expired with M1/M2 closed
ON – Both internal relays K1 and K2 are energized (Safety outputs 13-14 and 23-24 are closed. Auxiliary
output 31-32 is open)
Output (Green)
OFF – Both internal relays K1 and K2 are de-energized (Safety outputs 13-14 and 23-24 are open. Auxiliary
output 31-32 is closed.)
Flashing – Y1/Y2 Feedback Input open
16
Troubleshooting
on page 17 for probable cause
Troubleshooting
on page 17 for probable cause
on page 17 for probable cause
Troubleshooting
www.bannerengineering.com - tel: 763-544-3164
DUO-TOUCH® SG Two-Hand Control Modules
Muting Functions and Safety Stop Interface
Troubleshooting
on page 17 for probable cause.