After the vacuuming process
An acoustic signal will sound.
 Open the glass lid.
Danger of burning due to hot
surfaces.
The sealing bar and weld seam are
hot.
Do not touch the sealing bar or the
weld seam immediately after the
vacuuming process.
 Remove the vacuum sealing bag from
the vacuum chamber.
Before starting a new vacuuming
process, check that the vacuum
chamber and the sealing bar are
clean and dry.
Remove any soiling or liquid residues
if necessary.

Sealing the bag early

You can end the vacuuming process
before reaching the selected vacuuming
level and seal the bag early.
 Touch the  sensor.
The vacuuming process stops. After a
few seconds the bag will be sealed.
Successful sealing of the bag is only
possible when there is a minimum
vacuum (vacuum level 1) in the
chamber.
Touch the  sensor again if the
required vacuum level has not yet
been reached. For technical reasons, a
few seconds will elapse before the
bag is sealed.
Danger of injury caused by
implosion.
External glass containers can
implode during vacuuming.
Only use vacuum-proof containers
made of plastic or stainless steel.
We recommend caso
container sets if you wish to use
external containers. These containers
can be connected to the drawer
using the vacuum adapter supplied.