ERROR CODES

If any message other than the first two from the table were to come up, the
equipment should be switched off and on again until one of the first two are
seen.
After pressing
If any of the errors shown as (Service Department) are often repeated, ask
Fagor Automation's Customer Services Department about this.
The feedback alarm error will appear if the bit of the corresponding alarm
activating parameter for the axis has been set to "1". PAR08(1)=1.
In either case, to clear the display, press
If the axis value is flashing, this means that one of the travel limits established
by machine parameter has been exceeded. This error will be displayed if the
alarm activation parameter for the axis PAR08(2) = 1
If the DRO does not come on or goes out while running, check that the voltage
and ground outlets are as they should be. If an axis does not count, disconnect
the feedback connectors one by one. If the DRO comes on, it indicates a fault
in the feedback device. If the fault persists get in touch with Fagor Automation's
Customer Services Department about it.
Page: 16 - Operation Manual

APPENDIX

CLEAR
to access the counting mode, check the parameters.
CLEAR
.
NV-300T/301T Man: 9910 Soft: 2.xx