2.6)
Dispense sufficiently water from the post-mix valves to ensure that no sanitizing agent is left in the
system
Depending on the unit type (Over counter dispenser / large soda circuit installation with long python
runs, etc.) the amount of water that needs to be dispensed may vary.
Attention!
Dispense from each tap a few beverages to fully put the system back into operation again. The
cleaning / sanitization procedure must be documented accordingly and the documentation must
remain at the cooler (this may vary depending on local regulations).
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0
It must be ensured, that no cleaning / sanitizing agent remains in the dispense
system after service (risk of health injuries)!
The prove that all agent residues have been removed must be tested with indicator
or test papers (contact agent manufacturer) & must be documented
TRITON 200 HC