Remark -> Water filters :
In case the system is equipped with a water filter, the filter cartridge needs to be removed before doing the
cleaning / sanitization and replaced by a blind plug that allows bypassing the filter. Do not use any empty
service filter cartridges to flush the sanitizing agent into the system, as this will not allow a proper and
consistent level of sanitizing agent in the unit.
In addition, the high levels of agent passing through the dispenser when using such cartridges may damage
components such as sealings, O-rings, etc. in the dispenser.
Remark -> Carbonator- / Circulation pumps
With these kind of units the carbonator- and soda circulation pumps must be turned off during the cleaning /
sanitization process (otherwise foaming issues will occur).
Remark -> Stillwater lines inside the cooler
In case your equipment has still water lines, it must be made sure that these are also being cleaned /
sanitized.
In case your equipment currently does not use Stillwater, the line must be equipped with a stopcock to
manually drain sanitizing agent from this tube.
In case the Stillwater line is in general not being used on the cooler, it is recommended to disconnect this
line as close as possible from the water cycle and close the water line with a blind plug (this avoids areas
within the circuit which might not be sufficiently flushed).
Remark -> CO
- or Water pressure sensors on the dispense equipment
2
Depending on the type of equipment you may have CO
case of low CO
or low water supply cut the 24V power supply to the valves.
2
In order to still be able to operate the system during the sanitization process, it is required to short circuit
such sensors (make sure to put them back into operation after service).
Remark -> Post-mix valve blocks?
It is recommended to clean / sanitize the valve blocks separately. Especially valve blocks with an integrated
stop cock (e.g. Lancer block) need special care, as the gap in the stop cock allows bacteria to collect, which
might not be sufficiently treated with the sanitizing agent.
In case the dispenser is out of operation (without cooling) for more than 10 days, it is necessary to run the
cleaning- and sanitization procedure prior to putting the unit back into operation.
Should it be necessary, to open a once sanitized system again (e.g. to install a new water filter)
all opened connections must be disinfected with a sanitization spray prior to reconnecting.
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0