Cornelius Triton 200 HC Manual Operation page 17

Undercounter cooler
Table of Contents

Advertisement

2.6)
Flood the complete dispense system with the cleaning / sanitizing agent by operating the post-mix
valves. Ensure that on all valves clearly visible agent is being drawn.
Effect- / working time for the cleaning / sanitizing agent is min. 20 minutes!!
In the meantime remove the dispense nozzles from the valves and sanitize them manually by putting
them for 20 minutes into sanitizing agent. In case it is seen that the nozzles are heavily dirty, clean
the nozzles mechanically by using a clean brush and sanitization agent.
B.) Flushing-out of sanitization agent (to be done by experts)
1.)
Syrup Lines
1.1)
Disconnect the cleaning tank and bring out any remaining sanitizing agent from the syrup lines by
using CO
-gas. Afterwards close the CO
2
valves.
1.2)
Connect the water distributor and sufficiently flush clean water through the syrup lines (for this
please open only the syrup side of the dispense valves).
In case a hygiene water filter is being used with the dispenser, it is recommended to use for this
flushing the water coming from the hygiene filter.
Attention!
1.3)
Connect the syrup containers again to the syrup lines and dispense syrup on the post-mix valves
until a consistent flow of syrup occurs again.
2.)
Water lines
2.1)
Pressurize the water line to the cooler with CO
valves. This makes it easier to flush out any remaining agent from the system.
2.2)
Close the gas again and depressurize the unit via the dispense valves.
2.3)
Install a new water filter cartridge and reconnect the unit via the filter to the mains water line again
(refer to filter manufacturer guidelines in case the filter needs priming prior to use).
In case a hygiene filter is being used on the dispenser, it must be ensured that the new filter
cartridge is inserted prior to flushing the system with water. This ensures that a just sanitized system
is not being contaminated again by using poor quality mains water to flush out any remaining
sanitizing agent.
Spray the filter head and the connecting position of the filter cartridge with an adequate sanitizing
spray to avoid any introduction of bacteria again.
2.4)
Open the mains water supply. Pull the safety relieve valve on the carbonator bowl until only clean
water leaves the valve, to ensure that there are no residues of sanitizing agent left in the head area
of the carbonator bowl.
2.5)
Open the CO2-gas supply to the carbonator and reconnect the carbonator pump to the power
supply.
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0
It must be ensured, that no cleaning / sanitizing agent remains in the dispense
system after service (risk of health injuries)!
The prove that all agent residues have been removed must be tested with indicator
or test papers (contact agent manufacturer) & must be documented
-supply and depressurize the system via the dispense
2
-pressure and dispense all sanitizing agent from the
2
TRITON 200 HC
Manual operation undercounter cooler
Triton 200 HC
Page 17