Cornelius Triton 200 HC Manual Operation page 16

Undercounter cooler
Table of Contents

Advertisement

A.) Flushing-in of sanitization agent (e.g. P3 Ansep CIP from Ecolab) (to be done by experts)
1.)
Syrup Lines
1.1)
The product lines filled with syrup must first be flushed with water. For this an external water
distributor can be used to connect and flush several syrup lines simultaneously. The post-mix valves
should be operated on the syrup side only for flushing.
Attention!
1.2)
Connect the water distributor to the CO
Avoids, that the sanitizing agent is being diluted in the tubing. Afterwards close the CO
depressurize the complete system again.
1.3)
Fill your cleaning tank with the cleaning / sanitizing agent according to the mixing ratios given by the
manufacturer of the agent. (e.g. when using P3 from ECOLAB -> 50ml for 1 litre water = 5% solution)
In order to achieve a proper mixing in the cleaning tank, it is recommended to firs fill in the agent and
than top-of with clean water.
1.4)
Connect the syrup lines to the cleaning tank and dispense cleaning / sanitization agent from every
single dispense valve. Make sure that agent leaves from all installed taps.
2.)
Water Lines
2.1)
Close the water- + the CO
2.2)
Disconnect the water supply to the unit and cut the power supply to the carbonator pump in order to
avoid dry running of the pump (e.g. by pulling the plug of the pump).
2.3)
Connect the water line feeding the dispenser to CO
of the system. This ensures that the sanitizing agent that is afterwards flushed into the dispenser is
not being diluted e.g. in the carbonator bowl. Afterwards close the gas supply again and
depressurize the system.
2.4)
Connect the cleaning tank to the water inlet of the dispenser and pressurize the tank with approx. 0.3
MPa (3 bars) pressure
Attention!
2.5)
Pull the safety relieve valve on the carbonator bowl and carefully let some sanitizing
agent leave the valve. This ensures, that the carbonator bowl is flooded completely
with sanitizing agent all the way to the top.
Attention!
Cornelius Deutschland GmbH
Document no: TD1011602EN
Version A, 04.07.2019, Index 0
Gas driven syrup pumps must not see any positive pressures on the
incoming side of the pump, as this may damage the pumps.
2
-supply to the unit and depressurize the system with the taps
2
Remove any water filters before doing this!
Avoid that excessive amounts (= >50ml) of agent is being introduced into the water
bath, as this will carry the risk of corrosion of metal parts in the water bath.
In case larger amounts were spilled, the water in the water bath needs to be
replaced.
The cooler works with a membrane / diaphragm pump
Please make sure the pump is in operation when the sanitizing agent is being
flushed into the unit. This will ensure that all parts of the pump will come into contact
with the sanitizing agent.
-supply in order to drive the water out of the syrup lines. This
-gas pressure and drain all water from the tubing
2
TRITON 200 HC
-gas and
2
Manual operation undercounter cooler