Download Print this page
Nordson Coolwave 2 Instruction Sheet
Nordson Coolwave 2 Instruction Sheet

Nordson Coolwave 2 Instruction Sheet

Control board with contactor replacement kit
Hide thumbs Also See for Coolwave 2:

Advertisement

Quick Links

New Control Board
Fuses
Old Control Board
Figure 1
Old and New Versions of the Control Board
E 2018 Nordson Corporation
Coolwave
with Contactor Replacement Kit
NOTE: Retain the box used for shipping the control board and contactor to
comply with the conditions of warranty.
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation. A qualified and competent electrician must carry out all
electrical maintenance and servicing of this equipment.
WARNING: This equipment operates at high voltages up to 5000 volts dc
and is therefore potentially dangerous. The electrician servicing this
equipment must take all precautions.
WARNING: Isolate the equipment at the main disconnect or lockout before
removing any of the cover panels.
See Figure 1. The fuses on the new control board are in different locations
than on the old control board.
Fuses
Instruction Sheet
P/N 1099054-02
r
2 Control Board
New Control Board
Part 1099054-02

Advertisement

loading

Summary of Contents for Nordson Coolwave 2

  • Page 1 See Figure 1. The fuses on the new control board are in different locations than on the old control board. Fuses Fuses New Control Board Old Control Board Figure 1 Old and New Versions of the Control Board Part 1099054-02 E 2018 Nordson Corporation...
  • Page 2 Coolwave 2 Replacement Board and Contactor New Contactor Old 230V 50/60 Hz Contactor New 24Vdc Contactor Figure 2 Old and New Versions of Contactor Replacing the Control Board and Contactor Removing the Old Control Board and Contactor 1. Remove electrical power from unit.
  • Page 3 Coolwave 2 Replacement Board and Contactor 3. See Figure 4. On the main control board, disconnect the five electrical connectors (power harness and ribbon cables). Unclip Power Connector Push Connector Clips Out to Release Ribbon Cables Figure 4 Disconnecting Electrical Connectors 4.
  • Page 4 Coolwave 2 Replacement Board and Contactor Removing the Old Control Board and Contactor (contd) 5. See Figure 6. Loosen the terminal screws to remove the cables from the contactor. 6. Remove the four M4 screws securing the old contactor to the cabinet wall.
  • Page 5: Upgrade Kits

    Send return items to: UV System Group Nordson Corporation Warranty Division 444 Gordon Ave. Amherst, Ohio, 44001 Parts To order parts, call the Nordson Finishing Customer Support Center at (800) 433−9319 or contact your Nordson representative. Replacement Kit Part Description Note 1098890 KIT, board with contactor, Coolwave 2, standard NOTE A: To upgrade to the latest board and contactor, refer to the Upgrade Kits parts list.
  • Page 6 Coolwave 2 Replacement Board and Contactor Issued 8/18 Original copyright date 2010. Coolwave, Nordson, the Nordson logo, and Coolwave are registered trademarks of Nordson Corporation. All other trademarks are the property of their respective owners. Part 1099054-02 E 2018 Nordson Corporation...

This manual is also suitable for: