Nordson CoolWave 2 Instruction Sheet
Nordson CoolWave 2 Instruction Sheet

Nordson CoolWave 2 Instruction Sheet

Phase control board and cable replacement kit
Hide thumbs Also See for CoolWave 2:

Advertisement

Quick Links

Instruction Sheet
P/N 1102452-02
r
CoolWave
2 Phase Control Board
and Cable Replacement Kit
Use the Phase Control Board and Cable Kit to upgrade your CoolWave 2
power supply to the new configuration.
NOTE: Retain the box used for shipping the kit to comply with the
conditions of warranty.
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation. A qualified and competent electrician must carry out all
electrical maintenance and servicing of this equipment.
WARNING: This equipment operates at high voltages up to 5000 volts dc
and is therefore potentially dangerous. The electrician servicing this
equipment must take all precautions.
WARNING: Isolate the equipment at the main disconnect or lockout before
removing any of the cover panels.
Part 1102452-02
E 2018 Nordson Corporation

Advertisement

loading

Summary of Contents for Nordson CoolWave 2

  • Page 1 2 Phase Control Board and Cable Replacement Kit Use the Phase Control Board and Cable Kit to upgrade your CoolWave 2 power supply to the new configuration. NOTE: Retain the box used for shipping the kit to comply with the conditions of warranty.
  • Page 2 CoolWave 2 Phase Control Board and Cable Replacement Kit New Phase Control Board See Figure 1. Connectors CONN4 and CONN5 on the new phase control board have sockets rather than pins. Old Control Board New Control Board CONN5 CONN4 CONN5...
  • Page 3 CoolWave 2 Phase Control Board and Cable Replacement Kit Replacing the Phase Control Board and Cables Removing the Old Phase Control Board and Cables 1. Remove electrical power from unit. 2. See Figure 3. Remove the six M5 screws from the power supply cover.
  • Page 4 CoolWave 2 Phase Control Board and Cable Replacement Kit 5. See Figure 5. Two M4 screws and washers from the back side of the phase control board. Remove the phase control board and set it aside for proper disposal (see the Control Board and Cable Disposal section for instructions on proper disposal).
  • Page 5 CoolWave 2 Phase Control Board and Cable Replacement Kit Black Position 4T2 Black Position 2T1 Position 8T4 Black and Red Position 6T3 Contactor CR1 Wires Position 4 Position 5 Brown, Orange, Position 6 and Yellow Fuse Block F1 Wires Figure 7...
  • Page 6 Support Center at (800) 433−9319 or contact your Nordson representative. Replacement Kit Part Description Note 1612366 KIT, phase control board and cable, CoolWave 2 Issued 04/18 Original copyright date 2010. CoolWave, Nordson, and the Nordson logo are registered trademarks of Nordson Corporation. Part 1102452-02 E 2018 Nordson Corporation...

This manual is also suitable for:

1612366