SITE PREP TASKS
SELECTING THE SITE
Decide where to install the printer based on the following:
1. Space Requirements
2. Workstation Requirements
3. Environmental Requirements
4. Electrical Requirements
5. LAN Requirements
SPACE REQUIREMENTS
UNCRATED DIMENSIONS AND WEIGHTS
Make sure that the installation location can accommodate the printer's weight and dimensions, plus required
clearances. The installation location must be a stable flat surface capable of holding 220 pounds (100 kg) for
single material bay option, and 260 pounds (120 kg) for additional material bay option.
Height
Width
Depth
Weight
Material Bay Height
Material Bay Width
Material Bay Depth
Material Bay Weight
MINIMUM CLEARANCES
Sufficient rear and side clearances allow for proper air circulation, while sufficient front clearance allows enough
room for the oven door to be opened. The installation location must have a height clearance of 36-40 inches
(90-100 cm) for single material bay option, and 46-50 inches (117-127 cm) for additional material bay option.
Side Clearance
Rear Clearance
Front Clearance
ENVIRONMENTAL REQUIREMENTS
•
The uPrint SE/uPrint SE Plus printers are for indoor use only.
•
Air quality conditions with excessive solid particulates (conductive or non-conductive) may
result in system damage.
Air quality conditions in which airborne oils are allowed to accumulate on or within the printer
•
can damage the plastic components.
30 inches (76.2 cm)
26 inches (66 cm)
26 inches (66 cm)
130 pounds (59 kg)
6 inches (15.2 cm)
26 inches (66 cm)
26 inches (66 cm)
17 pounds (7.7 kg)
Minimum 6 inches (15.2 cm) on each side
Minimum 4.5 inches (11.4 cm)
Minimum 17 inches (43.2 cm)
2