Page 1
Power over the Ethernet PoE Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include: NetWay8MV - Eight (8) Port PoE Midspan Injector NetWay16MV - Sixteen (16) Port PoE Midspan Injector More than just power. DOC#: NETMV Rev. 050611...
Overview: Altronix NetWay8MV/NetWay16MV Managed Midspans provide power and pass data for PoE compliant cam- eras/edge devices . Cameras/edge devices may be located up to 100m from the NetWayMV unit . A NetWayXT/ NetWayXTX repeater module can be utilized to extend the distance an additional 100m for a total range of up to 200m .
8 . Port status LEDs on the NetWayMV will initialize when PoE devices are connected as follows: - LED will illuminate when devices are IEEE 802 .3af compliant . - LED will blink once and illuminate when devices are IEEE802 .3at compliant (PoE Plus) . 9 .
NetWay8MV/NetWay16MV User Interface and Programming: Note: A constant PC connection is not required for proper operations and is used as a local programming/monitoring tool only. Step 1 . Set Local Area Connection of your laptop to Static IP mode . Static IP address of the laptop must be assigned to the same network as the current IP address of NetWay8MV/NetWay16MV .
PoE Port Setup: Individual ports may be disabled if those ports are not used or to avoid the connection of unauthorized PoE devices . 1 . To disable one or more ports click on the Disable radio button(s) in the PoE column (Fig. 6, pg. 10) . 2 .
Configuring NetWay8MV/NetWay16MV for Network Connection: Since every Network Configuration is different, please check with your Network Administrator to see if your NetWay8MV/NetWay16MV should use static IP addresses, or DHCP assigned IP addresses and/an Inbound Port assignment prior to setting up network connection . 1 .
Note: Port 80 is the default port used for web browsing . Because of this, in order to prevent the average user from hosting a web server, most ISPs BLOCK traffic using port 80 from reaching the average site . If you only plan to monitor your NetWay8MV/NetWay16MV on a LAN, you can use port 80, and don’t have to concern your- self with routers .
NetWay8MV/NetWay16MV Rack Mount Chassis Mechanical Drawing and Dimensions: Fig. 7 0.75" (19.1mm) 1 2 3 4 5 6 7 8 RESET Ports + PoE -- SHUTDOWN ETHERNET 19.125" (485.8mm) 17.625" (447.7mm) 8.5" (215.9mm) 1.625" (41.3mm) (ON) The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock .
Altronix is not responsible for any typographical errors . 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www .altronix .com | e-mail: info@altronix .com | Lifetime Warranty | Made in U .S .A . MEMBER...