Doosan 12/154 Operation & Maintenance Manual page 49

Table of Contents

Advertisement

J1939
J1939
CUMMINS
SPN
FMI
CODE
4360
4
3143
4360
15
3164
4360
16
3231
4360
16
5247
4363
0
3165
4363
2
3148
4363
3
3146
4363
4
3147
4363
16
3235
4364
18
3582
4376
3
3577
4376
4
3578
4376
7
4157
4490
9
3367
4490
90
3368
4765
2
3315
4765
3
3314
4765
4
3313
4765
13
3325
4765
16
3251
4766
0
5387
4766
2
5386
J1939 SPN DESCRIPTION
Aftertreatment 1 SCR Catalyst
Intake Gas Temperature
Aftertreatment 1 SCR Catalyst
Intake Gas Temperature
Aftertreatment 1 SCR Catalyst
Intake Gas Temperature
Aftertreatment 1 SCR Intake
Temperature
Aftertreatment 1 SCR Catalyst
Outlet Gas Temperature
Aftertreatment 1 SCR Catalyst
Outlet Gas Temperature
Aftertreatment 1 SCR Catalyst
Outlet Gas Temperature
Aftertreatment 1 SCR Catalyst
Outlet Gas Temperature
Aftertreatment 1 SCR Catalyst
Outlet Gas Temperature
Aftertreatment 1 SCR
Conversion Efficiency
Aftertreatment 1 Diesel
Exhaust Fluid Return Valve
Aftertreatment 1 Diesel
Exhaust Fluid Return Valve
Aftertreatment 1 Diesel
Exhaust Fluid Return Valve
Specific Humidity
Specific Humidity
Aftertreatment Diesel
Oxidation Catalyst Intake
Temperature
Aftertreatment Diesel
Oxidation Catalyst Intake
Temperature
Aftertreatment Diesel
Oxidation Catalyst Intake
Temperature
Aftertreatment Diesel
Oxidation Catalyst Intake
Temperature
Aftertreatment Diesel
Oxidation Catalyst Intake
Temperature
Aftertreatment 1 Diesel
Oxidation Catalyst Outlet Gas
Temperature
Aftertreatment 1 Diesel
Oxidation Catalyst Outlet Gas
Temperature
OPERATING INSTRUCTIONS
J1939 FMI DESCRIPTION
Voltage Below Normal or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Least
Severe Level
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Abnormal Update Rate
Received Network Data in
Error
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Out of Calibration
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent or
Incorrect
CUMMINS DESCRIPTION
Aftertreatment 1 SCR Intake Temperature
Sensor Circuit - Voltage below normal, or
shorted to low source
Aftertreatment 1 SCR Intake Temperature -
Data Valid But Above Normal Operating Range
- Least Severe
Aftertreatment 1 SCR Intake Temperature -
Data Valid But Above Normal Operating Range
- Moderately Severe Level
Aftertreatment 1 SCR Intake Temperature -
Data Valid But Above Normal Operating Range
- Moderately Severe Level
Aftertreatment 1 SCR Outlet Temperature -
Data valid but above normal operational range
- Most Severe
Aftertreatment 1 SCR Outlet Temperature
Sensor - Data erratic, intermittent or incorrect
Aftertreatment 1 SCR Outlet Temperature
Sensor Circuit - Voltage above normal, or
shorted to high source
Aftertreatment 1 SCR Outlet Temperature
Sensor Circuit - Voltage below normal, or
shorted to low source
Aftertreatment 1 SCR Outlet Temperature -
Data Valid But Above Normal Operating Range
- Moderately Severe Level
Aftertreatment SCR Catalyst Conversion
Efficiency - Data Valid But Below Normal
Operating Range - Moderately Severe Level
Aftertreatment Diesel Exhaust Fluid Return
Valve - Voltage above normal, or shorted to
high source
Aftertreatment Diesel Exhaust Fluid Return
Valve - Voltage below normal, or shorted to low
source
Aftertreatment Diesel Exhaust Fluid Return
Valve - Mechanical system not responding or
out of adjust
Specific Humidity Sensor - Abnormal update
rate
Specific Humidity Sensor - Received Network
Data In Error
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Temperature - Data erratic, intermittent
or incorrect
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Temperature Sensor Circuit - Voltage
above normal, or shorted to high source
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Temperature Sensor Circuit - Voltage
below normal, or shorted to low source
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Temperature Swapped - Out of
Calibration
Aftertreatment 1 Diesel Oxidation Catalyst
Intake Temperature - Data Valid But Above
Normal Operating Range
Aftertreatment 1 Diesel Oxidation Catalyst
Outlet Gas Temperature - Data Valid But
Above Normal Operating Range - Most Severe
Level
Aftertreatment 1 Diesel Oxidation Catalyst
Outlet Gas Temperature - Data Erratic,
Intermittent, or Incorrect
45
12/154

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents