Doosan 12/154 Operation & Maintenance Manual page 40

Table of Contents

Advertisement

36
OPERATING INSTRUCTIONS
J1939
J1939
CUMMINS
SPN
FMI
CODE
1761
10
4769
1761
11
4739
1761
13
4732
1761
17
3497
1761
18
3498
1800
16
2263
1800
18
2264
1818
31
3374
2006
9
5133
2623
3
1239
2623
4
1241
2629
15
2347
2630
2
3478
2630
3
2571
2630
4
2572
2633
7
3616
2634
3
1776
2634
4
1777
2789
15
2346
12/154
J1939 SPN DESCRIPTION
Aftertreatment 1 Diesel
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
Exhaust Fluid Tank
Temperature
Aftertreatment 1 Diesel
Exhaust Fluid Tank Level
Aftertreatment 1 Diesel
Exhaust Fluid Tank Level
Battery 1 Temperature
Battery 1 Temperature
ROP Brake Control active
Source Address 6
Accelerator Pedal #1 Channel
2
Accelerator Pedal #1 Channel
2
Engine Turbocharger 1
Compressor Outlet
Temperature
Engine Charge Air Cooler 1
Outlet Temperature
Engine Charge Air Cooler 1
Outlet Temperature
Engine Charge Air Cooler 1
Outlet Temperature
Engine Variable Geometry
Turbocharger (VGT) 1 Nozzle
Position
Power Relay
Power Relay
Engine Turbocharger 1
Calculated Turbine Intake
Temperature
J1939 FMI DESCRIPTION
Abnormal Rate of Change
Root Cause Not Known
Out of Calibration
Data Valid but Below Normal
Operating Range - Least
Severe Level
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Not Available or Condition
Exists
Abnormal Update Rate
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Least
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Least
Severe Level
CUMMINS DESCRIPTION
Aftertreatment 1 Diesel Exhaust Fluid Tank
Level Sensor - Abnormal Rate of Change
Aftertreatment 1 Diesel Exhaust Fluid Tank
Level Sensor - Root Cause Not Known
Aftertreatment 1 Diesel Exhaust Fluid Tank
Level Sensor - Out of Calibration
Aftertreatment 1 Diesel Exhaust Fluid Tank
Level - Data Valid But Below Normal Operating
Range - Least Severe Level
Aftertreatment 1 Diesel Exhaust Fluid Tank
Level - Data Valid But Below Normal Operating
Range - Moderately Severe Level
Battery Temperature - Data Valid But Above
Normal Operating Range - Moderately Severe
Level
Battery Temperature - Data Va lid But Below
Normal Operating Range - Moderately Severe
Level
Roll Over Protection Brake Control Active -
Condition Exists
Source Address 6 - Abnormal Update Rate
Accelerator Pedal or Lever Position Sensor 2
Circuit - Voltage above normal, or shorted to
high source
Accelerator Pedal or Lever Position Sensor 2
Circuit - Voltage below normal, or shorted to
low source
Turbocharger Compressor Outlet Temperature
(Calculated) - Data Valid But Above Normal
Operating Range
Engine Charge Air Cooler Outlet Temperature
- Data erratic, intermittent or incorrect
Engine Charge Air Cooler Outlet Temperature
- Voltage above normal, or shorted to high
source
Engine Charge Air Cooler Outlet Temperature
- Voltage below normal, or shorted to low
source
Engine VGT Nozzle Position - Mechanical
system not responding or out of adjustment
Power Relay Driver Circuit - Voltage above
normal, or shorted to high source
Power Relay Driver Circuit - Voltage below
normal, or shorted to low source
Turbocharger Turbine Intake Temperature -
Data Valid But Above Normal Operating Range
- Least Severe

Hide quick links: