42
OPERATING INSTRUCTIONS
J1939
J1939
CUMMINS
SPN
FMI
CODE
3515
6
4744
3515
10
4243
3515
11
4745
3521
11
4768
3521
31
4235
3555
17
1943
3556
2
1932
3556
5
1977
3556
7
1964
3556
18
3167
3597
2
1117
3597
3
1939
3597
4
1941
3597
12
351
3597
18
1938
3610
2
3135
3610
3
3133
3610
4
3134
3667
2
31395221
3667
3
3139
3667
4
3141
3667
7
4484
3695
2
4213
12/154
J1939 SPN DESCRIPTION
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Property
Aftertreatment 1 Diesel
Exhaust Fluid Property
Ambient Air Density
Aftertreatment Hydrocarbon
Doser
Aftertreatment Hydrocarbon
Doser
Aftertreatment Hydrocarbon
Doser
Aftertreatment Hydrocarbon
Doser
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage #1
ECU Power Output Supply
Voltage #1
Aftertreatment Diesel
Particulate Filter Outlet
Pressure
Aftertreatment Diesel
Particulate Filter Outlet
Pressure
Aftertreatment Diesel
Particulate Filter Outlet
Pressure
Engine Air Shutoff Status
Engine Air Shutoff Status
Engine Air Shutoff Status
Engine Air Shutoff
Diesel Particulate Filter
Regeneration Inhibit Switch
J1939 FMI DESCRIPTION
Current Above Normal or
Grounded Circuit
Abnormal Rate of Change
Root Cause Not Known
Root Cause Not Known
Not Available or Condition
Exists
Data Valid but Below Normal
Operating Range - Least
Severe Level
Data Erratic, Intermittent or
Incorrect
Current Below Normal or
Open Circuit
Mechanical System not
Responding or Out of
Adjustment
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Bad Intelligent Device or
Component
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Data Erratic, Intermittent or
Incorrect
CUMMINS DESCRIPTION
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 Sensor Circuit - Current above
normal or grounded
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 - Abnormal Rate of Change
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 - Root Cause Not Known
Aftertreatment 1 Diesel Exhaust Fluid Property
- Root Cause Not Known
Aftertreatment 1 Diesel Exhaust Fluid Property
- Condition Exists
Ambient Air Density - Data Valid But Below
Normal Operating Range - Least Severe Level
Aftertreatment Doser - Data erratic, intermittent
or incorrect
Aftertreatment Doser Circuit - Current below
normal or open circuit
Aftertreatment Doser - Mechanical system not
responding or out of adjustment
Aftertreatment Doser - Data Valid But Below
Normal Operating Range - Moderately Severe
Level
Power Supply Lost With Ignition On - Data
erratic, intermittent or incorrect
ECU Power Output Supply Voltage 1 - Voltage
above normal, or shorted to high source
ECU Power Output Supply Voltage 1 - Voltage
below normal, or shorted to low source
Injector Power Supply - Bad intelligent device
or component
ECU Power Output Supply Voltage 1 - Data
Valid But Below Normal Operating Range -
Moderately Severe Level
Aftertreatment 1 Diesel Particulate Filter Outlet
Pressure - Data erratic, intermittent or incorrect
Aftertreatment 1 Diesel Particulate Filter Outlet
Pressure Sensor Circuit - Voltage above
normal, or shorted to high source
Aftertreatment 1 Diesel Particulate Filter Outlet
Pressure Sensor Circuit - Voltage below
normal, or shorted to low source
Engine Air Shutoff Status - Data erratic,
intermittent or incorrect
Engine Air Shutoff Circuit - Voltage above
normal, or shorted to high source
Engine Air Shutoff Circuit - Voltage below
normal, or
shorted to low source
Engine Air Shutoff - Mechanical System Not
Responding or Out of Adjustment
Aftertreatment Diesel Particulate Filter
Regeneration Inhibit Switch - Data erratic,
intermittent or incorrect