Doosan 12/154 Operation & Maintenance Manual page 45

Table of Contents

Advertisement

J1939
J1939
CUMMINS
SPN
FMI
CODE
3482
2
1925
3482
3
1923
3482
4
1924
3482
7
1963
3482
13
2741
3482
16
4568
3490
3
3224
3490
4
3223
3490
7
3225
3509
3
386
3509
4
352
3510
3
227
3510
4
187
3511
3
239
3511
4
238
3512
3
2185
3512
4
2186
3513
3
1695
3513
4
1696
3514
3
515
3514
4
516
3515
2
4242
3515
3
4233
3515
4
4234
3515
5
4743
J1939 SPN DESCRIPTION
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Fuel Enable
Actuator
Aftertreatment 1 Purge Air
Actuator
Aftertreatment 1 Purge Air
Actuator
Aftertreatment 1 Purge Air
Actuator
Sensor supply voltage 1
Sensor supply voltage 1
Sensor supply voltage 2
Sensor supply voltage 2
Sensor supply voltage 3
Sensor supply voltage 3
Sensor supply voltage 4
Sensor supply voltage 4
Sensor supply voltage 5
Sensor supply voltage 5
Sensor supply voltage 6
Sensor supply voltage 6
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
Aftertreatment 1 Diesel
Exhaust Fluid Temperature 2
OPERATING INSTRUCTIONS
J1939 FMI DESCRIPTION
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Out of Calibration
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Current Below Normal or
Open Circuit
CUMMINS DESCRIPTION
Aftertreatment Fuel Shutoff Valve - Data
erratic, intermittent or incorrect
Aftertreatment Fuel Shutoff Valve Circuit -
Voltage above normal, or shorted to high
source
Aftertreatment Fuel Shutoff Valve Circuit -
Voltage below normal, or shorted to low source
Aftertreatment Fuel Shutoff Valve - Mechanical
system not responding or out of adjustment
Aftertreatment Fuel Shutoff Valve Swapped -
Out of Calibration
Aftertreatment Fuel Shutoff Valve - Data Valid
But Above Normal Operating Range -
Moderately Severe
Aftertreatment Purge Air Actuator Circuit -
Voltage above normal, or shorted to high
source
Aftertreatment Purge Air Actuator Circuit -
Voltage below normal, or shorted to low source
Aftertreatment Purge Air Actuator - Mechanical
system not responding or out of adjustment
Sensor Supply 1 Circuit - Voltage above
normal, or shorted to high source
Sensor Supply 1 Circuit - Voltage below
normal, or shorted to low source
Sensor Supply 2 Circuit - Voltage above
normal, or shorted to high source
Sensor Supply 2 Circuit - Voltage below
normal, or shorted to low source
Sensor Supply 3 Circuit - Voltage above
normal, or shorted to high source
Sensor Supply 3 Circuit - Voltage below
normal, or shorted to low source
Sensor Supply 4 Circuit - Voltage above
normal, or shorted to high source
Sensor Supply 4 Circuit - Voltage below
normal, or shorted to low source
Sensor Supply 5 - Voltage above normal, or
shorted to high source
Sensor Supply 5 - Voltage below normal, or
shorted to low source
Sensor Supply 6 Circuit - Voltage above
normal, or shorted to high source
Sensor Supply 6 Circuit - Voltage below
normal, or shorted to low source
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 - Data erratic, intermittent or
incorrect
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 Sensor Circuit - Voltage above
normal, or shorted to high source
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 Sensor Circuit - Voltage below
normal, or shorted to low source
Aftertreatment 1 Diesel Exhaust Fluid
Temperature 2 Sensor Circuit - Current below
normal or open circuit
41
12/154

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents