Doosan 12/154 Operation & Maintenance Manual page 47

Table of Contents

Advertisement

J1939
J1939
CUMMINS
SPN
FMI
CODE
3703
31
2777
3713
31
3753
3750
31
3396
3926
18
4573
3936
7
3245
3936
14
4584
3936
15
1981
4094
31
3543
4096
31
3547
4097
3
2732
4097
4
2733
4097
7
2878
4182
4
3695
4183
4
3696
4184
4
3694
4185
31
1427
4186
31
1428
4187
31
1429
4188
31
1431
4223
31
1432
4331
18
4658
J1939 SPN DESCRIPTION
Diesel Particulate Filter Active
Regeneration Inhibited Due to
Inhibit Switch
Diesel Particulate Filter Active
Regeneration Inhibited Due to
System Timeout
Diesel Particulate Filter 1
Conditions Not Met for Active
Regeneration
Aftertreatment 1 Diesel
Exhaust Fluid Average
Consumption
Aftertreatment 1 Diesel
Particulate Filter System
Aftertreatment Diesel
Particulate Filter System
Aftertreatment Diesel
Particulate Filter System
NOx limits exceeded due to
Insufficient Diesel Exhaust
Fluid Quality
NOx limits exceeded due to
Empty Diesel Exhaust Fluid
Tank
Aftertreatment 1 Fuel Drain
Actuator
Aftertreatment 1 Fuel Drain
Actuator
Aftertreatment 1 Fuel Drain
Actuator
Generator Output Frequency
Adjust Potentiometer Circuit
Droop Adjust Potentiometer
Circuit
Gain Adjust Potentiometer
Circuit
Overspeed Shutdown Relay
Driver
Low Oil Pressure Shutdown
Relay Driver
High Engine Temperature
Shutdown Relay Driver
Pre-Low Oil Pressure Indicator
Relay Driver
Pre-High Engine Temperature
Warning Relay Driver
Aftertreatment 1 Diesel
Exhaust Fluid Actual Dosing
Quantity
OPERATING INSTRUCTIONS
J1939 FMI DESCRIPTION
Not Available or Condition
Exists
Not Available or Condition
Exists
Not Available or Condition
Exists
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Mechanical System not
Responding or Out of
Adjustment
Special Instructions
Data Valid but Above Normal
Operating Range - Least
Severe Level
Not Available or Condition
Exists
Not Available or Condition
Exists
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Mechanical System not
Responding or Out of
Adjustment
Voltage Below Normal or
Shorted to Low Source
Voltage Below Normal or
Shorted to Low Source
Voltage Below Normal or
Shorted to Low Source
Not Available or Condition
Exists
Not Available or Condition
Exists
Not Available or Condition
Exists
Not Available or Condition
Exists
Not Available or Condition
Exists
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
CUMMINS DESCRIPTION
Particulate Trap Active Regeneration Inhibited
Due to Inhibit Switch - Condition Exists
Diesel Particulate Filter Active Regeneration
Inhibited Due to System Timeout - Condition
Exists
Diesel Particulate Filter 1 Conditions Not Met
for Active Regeneration - Condition Exists
Aftertreatment 1 Diesel Exhaust Fluid Average
Consumption - Data Valid But Below Normal
Operating Range
Aftertreatment 1 Diesel Particulate Filter
System - Mechanical system not responding or
out of adjustment
Aftertreatment Diesel Particulate Filter System
- Special Instructions
Aftertreatment 1 Diesel Particulate Filter
System - Data Valid But Above Normal
Operating Range - Level
NOx limits exceeded due to Insufficient
Reagent Quality - Condition Exists
Aftertreatment Diesel Exhaust Fluid Tank
Empty - Condition Exists
Aftertreatment Fuel Drain Valve Circuit -
Voltage above normal, or shorted to high
source
Aftertreatment Fuel Drain Valve Circuit -
Voltage below normal, or shorted to low source
Aftertreatment Fuel Drain Valve - Mechanical
system not responding or out of adjustment
Generator Output Frequency Adjust
Potentiometer Circuit - Voltage below normal,
or shorted to low source
Droop Adjust Potentiometer Circuit - Voltage
below normal, or shorted to low source
Gain Adjust Potentiometer Circuit - Voltage
below normal, or shorted to low source
Overspeed Shutdown Relay Driver Diagnostic
has detected an error - Condition Exists
Low Oil Pressure (LOP) Shutdown Relay
Driver Diagnostic has detected an error -
Condition Exists
High Engine Temperature (HET) Shutdown
Relay Driver Diagnostic has detected an error
- Condition Exists
Pre-Low Oil Pressure Warning Relay Driver
Diagnostic has detected an error - Condition
Exists
Pre-High Engine Temperature Warning Relay
Driver Diagnostic has detected an error -
Condition Exists
Aftertreatment SCR Actual Dosing Reagent
Quantity - Data Valid But Below Normal
Operating Range - Mo
43
12/154

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents