J1939
J1939
CUMMINS
SPN
FMI
CODE
157
15
4727
157
16
553
157
18
559
168
16
442
168
17
3724
168
18
441
171
2
2398
171
3
249
171
4
256
171
9
3531
171
19
3532
174
0
266
174
2
535
174
3
263
174
4
265
174
16
261
175
0
214
175
2
425
175
3
212
175
4
213
175
16
421
J1939 SPN DESCRIPTION
Engine Injector Metering Rail 1
Pressure
Engine Injector Metering Rail 1
Pressure
Engine Injector Metering Rail 1
Pressure
Battery Potential / Power Input
1
Battery Potential / Power Input
1
Battery Potential / Power Input
1
Ambient Air Temperature
Ambient Air Temperature
Ambient Air Temperature
Ambient Air Temperature
Ambient Air Temperature
Engine Fuel Temperature 1
Engine Fuel Temperature 1
Engine Fuel Temperature 1
Engine Fuel Temperature 1
Engine Fuel Temperature 1
Engine Oil Temperature 1
Engine Oil Temperature 1
Engine Oil Temperature 1
Engine Oil Temperature 1
Engine Oil Temperature 1
OPERATING INSTRUCTIONS
J1939 FMI DESCRIPTION
Data Valid but Above Normal
Operating Range - Least
Severe Level
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Below Normal
Operating Range - Least
Severe Level
Data Valid but Below Normal
Operating Range - Moderately
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Abnormal Update Rate
Received Network Data in
Error
Data Valid but Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
Data Valid but Above Normal
Operational Range - Most
Severe Level
Data Erratic, Intermittent or
Incorrect
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Data Valid but Above Normal
Operating Range - Moderately
Severe Level
CUMMINS DESCRIPTION
Injector Metering Rail 1 Pressure - Data Valid
But Above Normal Operating Range - Least
Severe Level
Injector Metering Rail 1 Pressure - Data Valid
But Above Normal Operating Range -
Moderately Severe Level
Injector Metering Rail 1 Pressure - Data Valid
But Below Normal Operating Range -
Moderately Severe Level
Battery 1 Voltage - Data Valid But Above
Normal Operating Range - Moderately Severe
Level
Battery 1 Voltage - Data Valid But Below
Normal Operating Range - Least Severe Level
Battery 1 Voltage - Data Valid But Below
Normal Operating Range - Moderately Severe
Level
Ambient Air Temperature - Data erratic,
intermittent or incorrect
Ambient Air Temperature Sensor 1 Circuit -
Voltage above normal, or shorted to high
source
Ambient Air Temperature Sensor 1 Circuit -
Voltage below normal, or shorted to low source
Ambient Air Temperature - Abnormal update
rate
Ambient Air Temperature - Received Network
Data In Error
Engine Fuel Temperature - Data valid but
above normal operational range - Most Severe
Level
Engine Fuel Temperature - Data erratic,
intermittent or incorrect
Engine Fuel Temperature Sensor 1 Circuit -
Voltage above normal, or shorted to high
source
Engine Fuel Temperature Sensor 1 Circuit -
Voltage below normal, or shorted to low source
Engine Fuel Temperature - Data Valid But
Above Normal Operating Range - Moderately
Severe Level
Engine Oil Temperature - Data valid but above
normal operational range - Most Severe Level
Engine Oil Temperature - Data erratic,
intermittent or incorrect
Engine Oil Temperature Sensor 1 Circuit -
Voltage above normal, or shorted to high
source
Engine Oil Temperature Sensor 1 Circuit -
Voltage below normal, or shorted to low source
Engine Oil Temperature - Data Valid But
Above Normal Operating Range - Moderately
Severe Level
27