32
OPERATING INSTRUCTIONS
J1939
J1939
CUMMINS
SPN
FMI
CODE
677
3
584
677
4
585
697
3
2557
697
4
2558
701
14
4734
702
3
527
702
5
4724
702
6
4725
703
3
529
723
2
778
723
2
2322
723
7
731
729
3
2555
729
4
2556
748
9
3641
862
3
3733
862
4
3734
974
3
133
974
4
134
974
19
288
1072
3
2182
1072
4
2183
1073
3
2367
1073
4
2363
1075
3
2265
1075
4
2266
12/154
J1939 SPN DESCRIPTION
Engine Starter Motor Relay
Engine Starter Motor Relay
Auxiliary PWM Driver #1
Auxiliary PWM Driver #1
Auxiliary I/O #01
Auxiliary I/O #02
Auxiliary I/O #02
Auxiliary I/O #02
Auxiliary I/O #03
Engine Speed 2
Engine Speed 2
Engine Speed 2
Engine Intake Air Heater
Driver #1
Engine Intake Air Heater
Driver #1
Transmission Output Retarder Abnormal Update Rate
Crankcase breather Heater
Ciruit
Crankcase breather Heater
Ciruit
Remote Accelerator Pedal
Position
Remote Accelerator Pedal
Position
Remote Accelerator Pedal
Position
Engine (Compression) Brake
Output #1
Engine (Compression) Brake
Output #1
Engine (Compression) Brake
Output #2
Engine (Compression) Brake
Output #2
Engine Electric Lift Pump for
Engine Fuel Supply
Engine Electric Lift Pump for
Engine Fuel Supply
J1939 FMI DESCRIPTION
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Special Instructions
Voltage Above Normal, or
Shorted to High Source
Current Below Normal or
Open Circuit
Current Above Normal or
Grounded Circuit
Voltage Above Normal, or
Shorted to High Source
Data Erratic, Intermittent or
Incorrect
Data Erratic, Intermittent or
Incorrect
Mechanical System not
Responding or Out of
Adjustment
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Received Network Data in
Error
Voltage Above Normal or
Shorted to High Source
Voltage Below Normal or
Shorted to Low Source
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
Voltage Above Normal, or
Shorted to High Source
Voltage Below Normal, or
Shorted to Low Source
CUMMINS DESCRIPTION
Starter Relay Driver Circuit - Voltage above
normal, or shorted to high source
Starter Relay Driver Circuit - Voltage below
normal, or shorted to low source
Auxiliary PWM Driver 1 Circuit - Voltage above
normal, or shorted to high source
Auxiliary PWM Driver 1 Circuit - Voltage below
normal, or shorted to low source
Auxiliary Input/Output 1 - Special Instructions
Auxiliary Input/Output 2 Circuit - Voltage above
normal, or shorted to high source
Auxiliary Input/Output 2 Circuit - Current below
normal or open circuit
Auxiliary Input/Output 2 Circuit - Current above
normal or grounded circuit
Auxiliary Input/Output 3 Circuit - Voltage above
normal, or shorted to high source
Engine Camshaft Speed / Position Sensor -
Data erratic, intermittent or incorrect
Engine Camshaft Speed / Position Sensor -
Data erratic, intermittent or incorrect
Engine Speed / Position Camshaft and
Crankshaft Misalignment - Mechanical system
not responding or out of adjustment
Engine Intake Air Heater 1 Circuit - Voltage
above normal, or shorted to high source
Engine Intake Air Heater 1 Circuit - Voltage
below normal, or shorted to low source
Transmission Output Retarder - Abnormal
update rate
Crankcase Breather Filter Heater Circuit -
Voltage above normal, or shorted to high
source
Crankcase Breather Filter Heater Circuit -
Voltage below normal, or shorted to low source
Remote Accelerator Pedal or Lever Position
Sensor 1 Circuit - Voltage above normal, or
shorted to high source
Remote Accelerator Pedal or Lever Position
Sensor 1 Circuit - Voltage below normal, or
shorted to low source
SAE J1939 Multiplexing Remote Accelerator
Pedal or Lever Position Sensor System -
Received Network Data In Error
Engine Brake Actuator Driver 1 Circuit -
Voltage above normal, or shorted to high
source
Engine Brake Actuator Driver 1 Circuit -
Voltage below normal, or shorted to low source
Engine Brake Actuator Driver Output 2 Circuit -
Voltage above normal, or shorted to high
source
Engine Brake Actuator Driver Output 2 Circuit -
Voltage below normal, or shorted to low source
Electric Lift Pump for Engine Fuel Supply
Circuit - Voltage above normal, or shorted to
high source
Electric Lift Pump for Engine Fuel Supply
Circuit - Voltage below normal, or shorted to
low source