JRC Alphatron Marine AlphaDynaPos Operation Manual page 85

Ship automation and navigation system
Table of Contents

Advertisement

4.2 Appendix B: Checklist for Taking DP system into Operation
Before taking the DP2 system into operation perform items as listed in Table 8: DP system Operation Checklist on page
85:
Item Description
1
No (unacknowledged) alarms are present.
2
system is not in simulation mode.
3
PMS is in DP2 configuration.
4
The AlphaDynaPos DP system should be in a healthy condition. The system's health is indicated on
the DP Operator Panel.
5
On Sensor screen 2 MRU sensors must be selected.
6
On Sensor screen 2 Gyro sensors must be selected.
7
On Sensor screen 2 Wind sensors must be selected.
8
On Position Sensor page 2 DGPS sensors must be selected.
9
On Position Sensor page, Laser sensor must be selected if within reach of reflector.
Table 8: DP system Operation Checklist
85 | Appendices