Replacing the Dispense Assemblies
Remove the handset assembly
Reference numbers on F
page 13.
1. Disconnect power before beginning this procedure.
2. Remove 4 screws (A) to detach the motor cover (8).
Pull motor cover down.
3. Remove 6 screws (B) to remove pump cover (10).
Lift cover off pump.
4. Unplug handset wire (C) from control board (16) and
pull out through hole in pump cover.
5. Remove 4 screws (D) that secure the manifold (7) to
the pump. Remove hose/handset assembly.
Fluid may leak when screws (D) are removed.
Replace the handset assembly
Use Handset Replacement Kit 253279 (8 ft (2.44 m)
hose) or 253395 (25 ft (7.62 m) hose) to replace the
handset assembly.
1. Ensure o-ring (3) from replacement kit 253279 is in
the groove on the back of the manifold (7). Line up
manifold with fluid outlet (E) and replace 4 screws
(D) to secure the manifold to the pump.
2. Feed the handset wire (C) through the hole in the
pump cover and plug in to the control board (16).
3. Reseat pump cover (10) and replace 6 screws (B).
4. Reseat motor cover (8) and replace 4 screws (A).
5. Plug in power cord.
6. Pump is ready for use
311216J
. 1 refer to the Parts List on
IG
Replacing the Dispense Assemblies
.
B
A
F
. 1
IG
Never allow the pump to run dry of the fluid
being dispensed. A dry pump will quickly accel-
erate to a high speed, causing damage to the
pump. If the pump accelerates quickly or is run-
ning too fast, stop it immediately and check the
fluid supply. If the supply container is empty
and air has entered the system, prime the
pump with fluid.
The minimum flow rate generated by the pump
is 1.5 gpm (5.7 lpm). A new pump breaks in
over a period of time dependent on the level of
use. When the pump is completely broken in,
the flow rate generated by the pump may
increase to 1.6 - 1.7 gpm (6.1 - 6.4 lpm).
Replacing the Tapper Dispense
Tube
Use Tapper Dispense Tube Replacement Kit 253280 to
replace the tapper dispense assembly.
1. Disconnect power before beginning this procedure.
2. Remove dispense tube assembly by unscrewing
brass fitting.
3. Replace with new assembly
10
C
16
7
E
3
D
8
TI7051