20 | 0 986 610 825 | Service
6.
Service
6.1
Checking the tools for wear and dam-
age.
Prior to using, check the tools for wear and damage.
!
Always replace worn or damaged tools. Worn and
damaged tools can cause incorrect measurements,
injuries and damage components.
6.2
Cleaning tools
After use:
R
Rub tools with a lint-free cloth saturated with test oil
(see also section 5 "Consumables and lubricants").
R
Rub dirty threads with a lint-free cloth saturated
with Ballistol universal oil. Allow the universal oil to
act for a few minutes. Then wipe the threads with a
lint-free cloth and blow dry using clean compressed
air.
R
Place the cleaned tools into the tool case.
6.3
Vacuum connection adapters
Inspect the sealing ring of adapter 1 687 023 753 (con-
nection to UI-P 1.x) and adapter 1 687 023 754 (con-
nection to UI-P 2) prior to every use for:
R
Wear
R
Damage
!
Replace a worn or damaged sealing ring.
6.4
Digital dial gauge 0 986 613 422
6.4.1
Cleaning the dial gauge
!
Do not clean the dial gauge with alcohol-containing
cleaners.
R
Use only a dry, lint-free cloth to clean the dial gauge.
6.4.2
Checking the dial gauge
Have a certified testing agency, e.g. EP test service,
check the dial gauge every 2 years.
This is the responsibility of the user.
i
Retain the original packaging if possibly needed for
shipping and send the dial gauge only in the original
packaging.
|
1 689 989 245
2015-04-28
7.
Spare and wearing parts
Designation
Clamping device; UI-P 1.x
Clamping device; UI-P 2
Measuring device;
Remaining air gap UI-P 1.x / UI-P 2
Hold-down; UI-P 1.x
Hold-down; UI-P 2
Parts set; spring assembly UI-P 1.x / UI-P 2
Leak tester; leak checking UI-P 1.x
Leak tester; leak checking UI-P 2
Hose assembly; leak checking <)
Mounting unit; vacuum generation
Adapter; vacuum connection UI-P 2
Adapter; vacuum connection UI-P 1.x
Conversion kit;
mounting device 0 986 613 400
Measuring device; UI-P 1.x / UI-P 2
Anvil; UI-P 1.x / UI-P 2
Dial gauge
Measuring element
Graduated disc
Cans with screw-on cover (packaging unit
approx. 130 pcs)
<) Wearing part
* not available individually, only in set 0 986 613 462
Part number
0 986 610 312
0 986 610 313
0 986 610 314
0 986 610 318
0 986 610 826
0 986 613 392
0 986 610 829
0 986 613 391
0 986 610 795
0 986 610 897
1 687 023 753
1 687 023 754
0 986 613 393
0 986 613 394
0 986 610 898
0 986 613 422
1 683 521 101
0 986 613 425*
0 986 610 546
Robert Bosch GmbH