Opening Conduit Drill Guides

This step may be performed before or after mounting the inverter.
To open conduit drill guides:
 1. Move the Safety Switch ON/OFF/P switch and the inverter ON/OFF/P switch to OFF.
 2. Loosen the screws on the front cover of the Safety Switch, as shown below:
 3. Remove the Safety Switch cover.
 4. Open the required AC and DC conduit drill guides according to the conduits used in
the installation: The drill guides are located at the bottom and sides of the
enclosure, each with two sizes: ¾'' and 1''. Open the required drill guides, taking
care not to interfere with any of the internal components. It is recommended to use
a Unibit drill.
NOTE
Unused conduit openings and glands should be sealed with appropriate
seals.
Single Phase Inverter with HD-Wave Technology Installation MAN-01-00541-1.3
Figure 13: Opening the Safety Switch cover
Figure 14: Safety Switch drill guides