5 . Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and motion
detection into consideration (Fig . 5 .1)

Mounting procedure

• Separate the sensor and load module (Fig . 5 .2)
• Switch OFF power supply (Fig . 4 .1)
• Connect to mains power supply (Fig . 4 .2 / 4 .3)
• Push load module (H) into the flush box (Fig . 5 .3)
• Screw to support ring with box fixing screws (Fig . 5 .3).
• Select control dial and DIP switch settings on the sensor module (E)
(Fig . 5 .4) (➜ "6 . Function")
• Fit the sensor module (E) into the surround (G) and press together with the
load module (H). (Fig . 5 .5)
• Switch ON power supply (Fig . 5 .6)
6 . Function
Factory settings for control dials
Reach setting (J): IR 20 m / HF 8 m
Time setting (K): 30 s
Twilight setting (L): daylight mode
Reach setting IR (Fig . 5 .4 / J)
Adjustable in stages
– Control dial set to maximum = max. reach (approx. Ø 20 m)
– Control dial set to minimum = min. reach (approx. Ø 5 m)
Reach setting HF (Fig . 5 .4 / J)
Adjustable in stages
– Control dial set to maximum = max. reach (approx. Ø 8 m)
– Control dial set to minimum = min. reach (approx. Ø 1 m)
Time setting (Fig . 5 .4 / K)
Adjustable in stages.
The chosen stay-ON time can be set to between 30 s and 30 min via the
control dial. Once the brightness threshold is exceeded (presence logic), the
sensor switches OFF after the stay-ON time expires.
IQ mode (
)
If the control dial is set to (
), the stay-ON time is self-learning and adjusts
dynamically to user behaviour. The time cycle is determined by means of a
learning algorithm. The shortest time is 5 min, the longest time 20 min.
- 24 -
Twilight setting (Fig . 5 .4 / L)
The chosen response threshold can be set in stages from 2-1000 lux.
– Control dial set to
= twilight mode (approx. 2 lux)
– Control dial set to
= daylight mode (approx. 1000 lux)
➜ "Example applications" table, page 28
DIP switch factory settings
DIP 1 – DIP 5 = OFF
DIP 1 Normal/test mode (NORM/TEST) (Fig . 5 .4)
Test mode has priority over all other settings on the sensor switch and is used
for verifying proper working order as well for testing the detection zone. Irre-
spective of the ambient light level, the sensor switch activates the light to stay
ON for approx. 5 s in response to movement in the room (blue LED flashes on
detecting movement). All user-selected potentiometer settings apply in normal
mode (control dials). The sensor switch can also be set by means of the blue
LED without any load connected.
The DIP-switch test mode does not end automatically.
DIP 2 Fully automatic (AUTO) / semi-automatic (MAN) (Fig . 5 .4)
Semi-automatic mode (MAN):
The light only switches OFF automatically. Light is switched ON manually,
request light via the switch. The light stays ON for the stay-ON time selected.
Fully automatic mode (AUTO):
The light automatically switches ON in response to movement and OFF as am-
bient brightness increases as well as after the stay-ON time elapses. The light
can be switched ON and OFF manually at any time. This temporarily interrupts
the automatic switching function.
DIP 3 used / not used (Fig . 5 .4)
Selecting the "used" setting activates the integrated switch (A) as well as any
switch optionally connected to the S input. Selecting the "not used" setting de-
activates the integrated switch (A) as well as any switch optionally connected
to the S input and is therefore without any function. The switch also influences
interconnection with the P conductor. (➜ "4 . Installation")
DIP 4 switch ON / ON/OFF (Fig . 5 .4)
In the ON/OFF setting, the light can be switched ON and OFF manually at any
time. In the ON setting, light can no longer be switched OFF manually. The
stay-ON time starts from the beginning again each time the switch is pressed.