• Thoroughly clean the smoke exhaust system: contact a professional chimney sweep for
this purpose;
• Clean all dust, spider webs, etc., the area behind the panels of the inner cladding,
specifically the fans.
• Disconnect the power cable;
• Leave the fire door ajar to avoid humidity from getting into the fumes duct and risk oxidising the
inner surfaces.
Routine and special maintenance
9.13
These operations must be scheduled at least yearly with a Technical Support Centre and are
required to ensure the product is kept efficient and ensure safe operation.
• Thoroughly clean the combustion chamber and the heat exchanger;
• Smoke motor cleaning, dismantling and cleaning the smoke exhaust duct, new silicone where
required;
• Inspection and checking the gasket seals, replacement and silicone application where required;
• Tank, emptying and cleaning;
• Checking the electrical part and electronic components;
• Cleaning and checking the tube and vacuum gauge;
• Checking and replacing, if required, of components that are subject to wear: brazier, resistance,
ash drawers, etc.
• In models with DHW production, we recommend having the exchanger undergo yearly
maintenance to remove limestone sediments and mineral salts.
42