• CAUTION: if during the ignition stage, ignition does not occur and you notice a lot of
smoke in the combustion chamber, immediately turn off the stove and replace the pellets
being used, as it may be too moist. Forcing ignition could make your stove a hazard.
• CAUTION: if during cleaning, you find traces of spongy or hard (however not ash) pellets,
replace the pellet being used, as this residue may come from scraps of low quality
sawdust not usable in this type of stove. Forcing ignition can cause a fire or strong
production of fumes in the chimney.
• CAUTION: monitor proper combustion of the pellets in the brazier. Should you detect
accumulations of unburned pellets, IMMEDIATELY TURN OFF the stove and contact the
service centre.
• CAUTION: pay the utmost attention when children are present to prevent them from
standing in front of the stove.
6.1

Console description

The console displays information about boiler operating status. Access the menu to view various
types of displays and adjust the settings available depending on the level of access.
Depending on the operating mode, the displays may have different meanings based on their
position on the display.
Below is a list of meanings of LEDs found on control panels:
Room thermostat LED
Chrono LED
Igniter plug LED
Screw feeder on LED
Smoke fan LED
Exchanger LED
Pump on LED
Alarms LED
The LED is on when it is connected to an external room thermostat and it is
closed
The LED switches on when the programmable thermostat is activated;
meaning, if user parameter 03-01-01 enables chrono, it is different from off
The LED switches on when the igniter plug is powered.
The LED switches on in the time intervals in which the pellet screw feeder is in
operation.
The LED switches on when the smoke fan is on.
The LED switches on when the fan is in operation (air version)
The LED switches on when the pump/circulator is in operation (only with
Hydro and boiler models)
The LED switches on when there is an alarm activated on the boiler