Use - LAMINOX Idro TERMOBOILER Mini Series Instructions For Installation, Use And Maintenance Manual

Pellet boiler
Table of Contents

Advertisement

The Termoboiler line boilers are designed to operate 24/7 365 days a year. The boiler has been
designed to maintain the water it contains above 70°C. This way, water will always be available for
the domestic environment heat request. This does not involve continuous pellet consumption, as
the boilers are adjusted automatically according to the heat requests of the connected utility.
Therefore, to guarantee proper operation, work parameters and configurations must be set
correctly.
Below the essential points to be set correctly:
• The heat requirement from the domestic heating system must occur via closing the
external thermostat contact and must therefore be connected to an external contact for
example coming from a commercial timed thermostat located inside the house. (see paragraph
6.3.6).
• The boiler power level must be set to 5 and water temperature must be set to 70°C. (see
paragraph 6.3.3).
With these settings, the operation periods will be controlled directly from the programmable
thermostat inside the house.
Even if available, we do not recommend activating the activation and deactivation
programming, leaving the programmable thermostat to control boiler deactivation (stand-by
mode).
All local regulations, including those relating to national and European regulations, must be
observed when installing the unit.
Improper installation or use of the device can result in forfeiture of the warranty.
Do not use the unit as an incinerator or in any other way other than that for which it was designed.
Do not use liquid fuels.
Do not make any unauthorised modifications to the device.
Only use original replacement parts recommended by the manufacturer.
In general
• Make sure that the room where the stove is to be installed offers sufficient ventilation (see section
''1.3 External air intake vent'').
• Make sure that all exhaust system joints are hermetically sealed with silicone (no cementing), are
resistant to heat (250°C) and are not damaged.
• Periodically check (or have someone check) the cleanliness of exhaust fumes.
• CAUTION: keep all flammable products well away from the stove when it is operating
(MINIMUM: 100 cm from the front wall).
• CAUTION: to prevent fumes from leaking, the combustion chamber must be kept closed
except during cleaning operations, to be carried out with the stove off.
• CAUTION: removing the safety guard inside the tank is strictly prohibited.
• CAUTION: in case of pellet resupply with stove on, make sure that the pellet has not ended
and the fame is always present in the brazier. If the flame is extinguished a dense white
smoke may form, able to cause an explosion in the combustion chamber. The explosion
can be of such intensity as to break the glass of the dire door. Therefore pay attention to
never stay in front of the stove during ignition stage if the fuel releases a dense smoke.
The stove is however equipped with all safety systems required to minimise the glass
breakage risk.
• CAUTION: prevent the fuel bag to come into contact with hot surfaces.
• CAUTION: remove any residue of unburned pellets caused by failed ignitions before
starting the stove again.