6.1.1 Display functions
BUTTON 4
ON/OFF
BUTTON 5
POWER REDUCTION
BUTTON 6
POWER INCREASE
BUTTON 3
MENU SELECTION
BUTTON 1
PARAMETER
ADJUSTMENT
(INCREASE)
BUTTON 2
PARAMETER
ADJUSTMENT
(DECREASE)
6.2

First ignition

Before igniting the boiler, you must have a qualified technician perform "FIRST START-UP" and
calibration. For this purpose, we advise you to contact personnel part of our network of authorised
support centres.
The company assumes no responsibility for malfunctions due to improper installation,
failure to install, incorrect first ignition, or improper use.
Make sure that electrical and plumbing connections have been performed properly. Also check that
the hydraulic system has a sufficient expansion tank for maximum safety. Please note that
expansion is calculated considering 10% of the whole volume contained in the system. Any
damage to the system or to equipment will not be considered under warranty. The presence of the
tank fitted on the unit does not guarantee adequate protection against sustained thermal expansion
of the system water.
Fill up the system through a refill valve (to be provided externally to the boiler). During recovery, it
is advisable not to exceed a maximum pressure of 1 bar. The pressure may be read directly on the
display.
The water loading phase should be simultaneous to air exhaust.
Before turning on the boiler, also check that the brazier is positioned correctly inside the
combustion chamber.
The first few start-ups, it may give off odours due to the evaporation of paint or grease. Simply
ventilate the room to make the odour go away, avoiding prolonged exposure as vapours can be
harmful to people or animals. Do not allow children to stay in the room during this first phase.
When the tank is loaded for the first time, the feed screw must fill up for a given period. During this
time, pellets will not be distributed within the combustion chamber. To overcome this difficulty, use
the command "initial load" in menu 7 of the control panel (see further details below).
Functions:
Manual boiler start-up and shut-down
Exit from a sub-menu
Exit from shut-down or alarm (and passage to off status)
Functions:
Reduction in set power value
Switching from a sub-menu to the previous one
Functions:
Increase in set power value
Switching from a sub-menu to the next one
Functions:
Switching to sub-menus
Switching to programmable thermostat and clock programming
Switching to technical parameters programming.
Functions:
Switching to boiler water temperature setting mode
In temperature setting mode, it increases the set value
In technical parameter setting mode, it increases the set value
In work mode, it activates water setting in the boiler
Functions:
In temperature setting mode, it reduces the set value.
In technical parameter setting mode, it reduces the set value.
24