7.5
Menu 06 "BUZZER MODE"
When "off," acoustic signal is disabled in the event of an alarm. When "on," sets off a buzzer when
an alarm is activated.
7.6
Menu 07 "INITIAL LOAD"
When the display shows the message "OFF," allows you to preload pellets for a time equal to 90".
Press the "1" key to start and "4" key to stop. Once preloading is completed, remove the loaded
pellets from the brazier.
7.7
Menu 08 "BOILER STATUS"
The boiler status menu shows the current state of the boiler, showing some sensor values and
other variables inside the boiler. Four pages displayed in succession are available. This menu is for
qualified service personnel use.
7.8
Menu 09 "TECHNICAL CALIBRATIONS"
This menu is protected by an access key and is intended for qualified service personnel.
7.9
Menu 10 "PELLET TYPE"
This menu allows you to simultaneously increase or decrease all pellet lowering parameters
(quantity of pellets and brazier loading).
The set default value is 00. Press keys (1) and (2) to modify said value from -9 to +9.
For each unit, pellet load times are increased or decreased by 2.5 %.
7.10 Menu 11 "FIREPLACE TYPE"
This menu allows users to simultaneously increase or decrease all smoke fan parameters (draft).
The set default value is 00. Press keys (1) and (2) to modify said value from -9 to +9.
For each unit, smoke motor revs are increased or decreased by 2.5%.
35