  • Page 1 Tyscor V 2 central suction unit Installation and Operating Instructions 0297 7177100004L02 ...
  • Page 3: Table Of Contents

    Contents Important information Installation 1 About this document                3 6 Requirements                     13 11 Warnings and symbols            3 61 Installation/setup room           13 12 Copyright information             3...
  • Page 4 Contents Troubleshooting 14 Tips for operators and service technicians                       24 141 General faults                  24 142 Error messages in Tyscor Pulse     25 15 Transporting the unit               26 Appendix...
  • Page 5: Important Information

    Important information About this document The signal word differentiates between four levels of danger: These installation and operating instructions – DANGER form part of the unit Immediate danger of severe injury or death If the instructions and information in – WARNING these installation and operating instruc- Possible danger of severe injury or death tions are not followed, Dürr Dental cannot –...
  • Page 6: Safety

    Important information Safety 2.3 General safety notes When operating this device always observe all Dürr Dental has designed and constructed this guidelines, laws, and other rules and regula- device so that when used properly and for the tions that are applicable at the site of opera- intended purpose there is no danger to people tion or property Nevertheless, residual risks can re-...
  • Page 7: 25 Specialist Personnel

    Important information 2.5 Specialist personnel 2.8 Transport Operation WARNING Persons who operate the units must ensure safe Infection due to contaminated unit and correct handling based on their training and Disinfect the unit before transport knowledge Close all media connections Instruct or have every user instructed in han- The original packaging provides optimum pro- dling the unit tection for the device during transport...
  • Page 8: Product Description

    Product description Overview Tyscor VS 2 suction unit Condensate separator Mains cable with country-specific mains plug Hose LW 50 (06 m) Hose LW 50 (15 m) Hose LW 20 Set of connection fittings 7177100004L02 1510V002SE...
  • Page 9: 31 Scope Of Delivery

    Product description 3.1 Scope of delivery The following items are included in the scope of delivery (possible variations due to country-spe- cific requirements and/or import regulations): Tyscor V 2 .... 7177-01/. . . – Suction unit – 230 V, 1~, 50/60 Hz – Set of connection fittings – Condensate separator –...
  • Page 10: Technical Data

    Product description Technical data Electrical data Nominal voltage 230, 1~ Mains frequency 50 - 60 Nominal current Rated power Fuses 2x T 40 AH / 250 V~ (IEC 60127-2) Type of protection IP 21 Protection class Connections ∅ 50 Vacuum connection (external) ∅...
  • Page 11 Product description Ambient conditions during storage and transport Temperature °C -10 to +60 Relative humidity < 95 Ambient conditions during operation Temperature °C +10 to +40 Relative humidity < 70 Classification Medical Devices Directive (93/42/EU) Class IIa 7177100004L02 1510V002SE...
  • Page 12: 41 Model Identification Plate

    Product description 4.1 Model identification plate The model identification plate can be found on the upper part of the housing Model identification plate 4.2 Conformity assessment This device has been subjected to conformity acceptance testing in accordance with the cur- rent relevant European Union guidelines This equipment conforms to all relevant require- ments 7177100004L02 1510V002SE...
  • Page 13: Operation

    Product description Operation Vacuum connection Network connection Mains connection with mains fuses Control connection Condensate connection Exhaust air connection Red LED - radial blower fault Red LED (no function) Green LED - ready for operation 10 Blue LED - "start" signal 11 Start button The V suction unit is used in "dry"...
  • Page 14: 53 Leds And Settings

    Product description 5.3 LEDs and settings LEDs: – The green LED lights up continuously when the unit is ready for operation – The red LED lights up when there is a fault – The blue LED lights up when a "start" signal is present from the treatment unit 5.4 Tyscor Pulse (optional) The software is connected via the network to the units from Dürr Dental and displays the current sta- tus as well as messages and errors...
  • Page 15: Installation

    Installation Requirements 6.3 Pipe materials Only use vacuum-sealed HT-waste pipes The unit can be installed on the same level as manufactured from the following pipe mate- the surgery room or in a floor below rials: Further information can be found in our – Polypropylene (PP), suction planning information leaflet Order –...
  • Page 16: 66 Information About Connecting

    Installation System components 6.6 Information about connecting cables The system components listed below are re- quired or recommended for various procedures Mains supply cable or for installation Only use the supplied mains cable to connect the device 7.1 Exhaust air filter Control cable For reasons of hygiene, we recommend the in- stallation of an exhaust air filter in the exhaust air Installation type Line layout (minimum...
  • Page 17: Installation

    Installation Installation 8.2 Installation and routeing of hoses and pipes The actual connection can vary depend- Establish connections between the pipe sys- ing on the chosen installation option The tem and the suction unit using the flexible connection shown is only an example hoses supplied This will prevent vibrations from being transmitted to the pipe system 8.1 Mounting the condensate The connection between the pipe line and...
  • Page 18: 83 Electrical Connections

    Installation 8.3 Electrical connections Fasten the socket piece to the control line and connect to the suction unit Connect the mains cable to the suction unit and plug it into the socket-outlet Plug the network cable for the Tyscor Pulse into the network connection (optional when using Tyscor Pulse) 7177100004L02 1510V002SE...
  • Page 19: 84 Pcb Electrical Connections

    Installation 8.4 PCB electrical connections E1 + X1 Control voltage output, 24  V  DC, 25  VA, control signal input X2 Network connection X3 Supply voltage 230 V X5 Motor control fan connection 2 X6 Service interface X7 SD card holder (for Micro SD), optional X9 Separation motor RPM monitor X10 Separation motor supply voltage X11 Motor control fan connection 1...
  • Page 20: Commissioning And First Start-Up

    Installation Commissioning and first Click on Unit manager in the side bar The list of units appears A symbol displays start-up the connection status to the software: Carry out a functional inspection of the system The device is present in the network and check the connections for leaks and connected to the software Attach and screw on the covers...
  • Page 21 Installation Selecting the operating mode Transferring the maintenance schedule to the software The suction unit can be used in various operat- ing modes Depending on the installation situa- tion and power requirements, one of the follow- We recommended transferring the tasks from ing operating modes can be selected: Eco, Bal- the maintenance schedule (see "13 Mainte- anced or Boost On delivery, the suction ma- nance") into the maintenance schedule of the...
  • Page 22: Pulse

    Usage 10 LEDs 11 Monitoring the device with Tyscor Pulse Further information on Tyscor Pulse can be found in the software help and in the Tyscor Pulse manual, order number 9000-619-22 11.1 Monitoring operation The device must have been added to the cock- pit for the graphical device block to be shown in the cockpit Red LED - fault Green LED - ready for operation...
  • Page 23: 113 Completing The Task

    Usage 12 Disinfection and cleaning As soon as a message concerning a de- vice occurs, the symbol in the task bar (or Mac OS menu bar) also changes to NOTICE the relevant message symbol If required Device malfunctions or damage due to by the message an acoustic signal also use of incorrect media sounds Guarantee claims may become invalid as...
  • Page 24: 123 Once Or Twice A Week Before The Midday Break

    Usage 12.3 Once or twice a week before the midday break Under harsher conditions (eg hard water or frequent use of prophylaxis powders) 1x daily before the midday break The following are required for cleaning: – Material-compatible, non-foaming special cleaning agents that have been approved by Dürr Dental, eg MD 555 Cleaner –...
  • Page 25: 13 Maintenance

    Usage 13 Maintenance Wear protective equipment to avoid any danger of infection (eg liquid-tight protective gloves, protective goggles, face mask) Maintenance interval Maintenance work Every 1-2 years Replace the exhaust air filter (where fitted) 7177100004L02 1510V002SE...
  • Page 26: Troubleshooting

    Troubleshooting 14 Tips for operators and service technicians Any repairs above and beyond routine maintenance must only be carried out by suitably quali- fied personnel or by one of our service technicians Before working on the device or in case of danger, disconnect it from the mains (e g pull the mains plug) CAUTION Electric shock due to capacitor discharge...
  • Page 27: 142 Error Messages In Tyscor Pulse

    Troubleshooting 14.2 Error messages in Tyscor Pulse The error messages are displayed in Tyscor Pulse If the device is not connected to the net- work, the messages can be read via a terminal client (e g PuTTY) Problem Probable cause Solution Vacuum motor overheated Motor suction stage defective Replace the suction stage CPU overheated Insufficient ventilation or poor set- Check the setup conditions,...
  • Page 28: 15 Transporting The Unit

    Troubleshooting 15 Transporting the unit Wear protective equipment to avoid any danger of infection (eg liquid-tight pro- tective gloves, protective goggles, face mask) Before disassembly clean and disinfect the suction unit and the suction system using a disinfectant approved by Dürr Dental Disinfect a defective unit using a suitable sur- face disinfection agent Disassemble the condensate separator...
  • Page 29: Appendix

    Appendix 16 Information about EMC in accordance with EN 60601-1-2 16.1 General notes This information contains excerpts from the international standards for electrical medical devices It must be observed when installing Dürr Dental devices or combining them with products of other manufacturers If you are uncertain about anything, please refer to the complete standard 16.2 Abbreviations Electromagnetic compatibility High frequency...
  • Page 30 Appendix Resistance to electromagnetic interference (immunity) for all devices and systems The device is designed for use in electromagnetic environments specified below The customer or op- erator of the device should ensure that the device is operated such an environment Interference im- IEC 60601 - test Compliance level Electromagnetic environment munity tests level - guidelines ±8 kV contact dis- ±8 kV contact dis- Electrostatic dis- Floors should be made of wood...
  • Page 31 Appendix Electromagnetic interference immunity for devices or systems that are not life-sustaining Portable and mobile communication devices should not be used any closer to the unit (including ca- bles) than the recommended safety distance, which is calculated based on the applicable formula for the transmission frequency Interference im- IEC 60601 - test Compliance Recommended safety distance munity tests level level...
  • Page 32 Appendix Recommended safety distance between portable and mobile HF communication devices and the unit The device is designed for use in the electromagnetic environments specified below, in which the HF disturbance variables are controlled The customer or the operator of the device can help to prevent electromagnetic interference by maintaining the minimum distances between mobile HF communica- tion equipment (transmitters) and the device as recommended below in accordance with the maxi- mum output line of the communication equipment Keep a minimum distance of 30 cm between the device and mobile communication devices...
  • Page 33 Appendix 16.4 Calculation table If the measured values deviate from the standard, the values are specified in chapter "4 Technical data" The safety distances can then be calculated in the tables shown below    Rated power of the transmitter in Watts (W) in accordance with the specifications of the transmitter manufacturer Compliance level for the test in acc with IEC61000-4-6 Compliance level for the test in acc with IEC61000-4-3...
  • Page 36 Hersteller/Manufacturer: DÜRR DENTAL SE Höpfigheimer Str. 17 74321 Bietigheim-Bissingen Germany Fon: +49 7142 705-0 www.duerrdental.com info@duerrdental.com...

Table of Contents