JUKI LK-1910 Engineer's Manual page 79

Computer-controlled high speed bar tacking industrial sewing machine, computer-controlled high speed bar tacking industrial sewing machine with input function
Hide thumbs Also See for LK-1910:
Table of Contents

Advertisement

(38) Magnet type wiper operation time function
Function No. : 054
Item : 1 Wiper-on time
Indication
0 to 999 ms
Item : 2 Wiper return waiting time
0 to 999 ms
Indication
(39) Pneumatic type wiper operation time function : This function is not used with the standard machine.
Function No. : 055
Item : 1 Wiper-on time
Indication
0 to 999 ms
Item : 2 Wiper return waiting time
0 to 999 ms
Indication
(40) Intermediate presser operation time function : Use this function without changing the standard setting.
Function No. : 056
Item : 1 Setting the length of waiting time after the intermediate presser has come down.
0 to 999 ms
Indication
Item : 2 Setting the length of waiting time after the intermediate pesser has gone up.
0 to 999 ms
Indication
Function : Time setting of the magnet type wiper operation
[Contents] Setting of the wiper ON time : Initial setting 50
[Contents] Setting of the length of time between the completion of wiper
operation and the operation of the next device : Initial setting 100
Wiper signal
Wiper signal
Function : Time setting of the pneumatic type wiper operation
[Contents] Setting of the wiper ON time : Initial setting 100
[Contents] Setting of the length of time between the completion of the wiper
operation and the operation of the next device : Initial setting 100
Wiper signal
Wiper signal
Function : Time setting of the intermediate presser operation
[Contents] If the sewing machine starts running immediately after the intermediate
presser has operated, the intermediate presser is likely to interfere with
the needle bar since the intermediate presser has a mechanical delay. To
prevent this, the sewing machine starts to run after the length of time
specified for this item has passed. : Initial setting 50
[Contents] After the intermediate presser has gone up, and after the specified time in
this item has passed, the next operation is made. : Initial setting 150
74
T 1
Setting of the item 1
T 2
Setting of the item 2
Other device actuates.
T 1
Setting of the item 1
T 2
Setting of the item 2
(Set level 2)
(Set level 2)
(Set level 2)
(Set level 2)
Other device actuates.
(Set level 2)
(Set level 2)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lk-1920Lk-1930

Table of Contents