I
9.1.5 Envlrorvnental condition
Durability and resistance to environmental conditions: protected from the weather (IEC 60945)
(1) Equipment category
: Protection against weather
(2) Operating temperature
: -15°C to +550C (IEC 60945)
(3) Storage temperature
: -25°C to +750C
(4) Humidity resistance
:After 4 hours at + 40
o
C, 93% RH, no abnormality
(5) Vibration resistance
:amplitude up to 2 to 5Hz and 13.2 Hz± 1 mm ± 10%
(6) Ingress Protection
: 13.2 to 100 Hz Maximum acceleration 7 m I
5
2
After sweeping in three axial directions, testing of 2 hours or
more.
No abnormality
: IP22
I
9.1 .6 Supported Interface sentences
Independent of the connection of the BAM
Indication
Sentence format
Supported sentence formatters
IDATAINI
Input data
IEC61162-1
LongitudeA..atitude
RMC,GGA,GLL
IDATAOU]
(NMEA Ver 1.5 - Time I Position
2.3)
Datum Reference
DTM
Speed Over Ground (SOG)
RMC,VTG
Course Over Ground (COG)
RMC,VTG
Heading
HDT
RateofTum
ROT
IEC61097-6
Request NAVTEX messages
NRM
Set NAVTEX mask
NRM
Output data
IEC61097-6
New NAVTEX received messaae
NRX
Set NAVTEX mask
NRM
When connected to the
BAM
Indication
Sentence format
Supported sentence formatters
IDATAINI
Input data
IEC61162-1
Alert command
ACN
IDATAOU]
(NMEA Ver 4.1)
Output data
IEC61162-1
Alert sentence
ALF
(NMEA Ver 4.1)
Cyclic alert list
ALC
Heartbeat supervision
HBT
sentence
Alert command
refuse
ARC
When not connected to the BAM
Indication
Sentence format
Supported sentence formatters
IDATAINI
Input data
IEC61162-1
Acknowledge alarm
ACK
IDATAOU]
(NMEA Ver 1.5 -
2.3)
Output data
IEC61162-1
Set alarm state
ALR