Panel Circuit Board Removal - Epson Perfection 3200 Photo Service Manual

Color image scanner
Hide thumbs Also See for Perfection 3200 Photo:
Table of Contents

Advertisement

EPSON Perfection 3200 Photo

4.2.4 Panel Circuit Board Removal

1. Release the carriage lock. (See Section 4.2.1.)
2. Remove the document cover. (See Section 4.2.2.)
3. Remove the upper cover. (See Section Section 4.2.3.)
4. Remove the two screws (CPS, M3x4), and then remove the panel circuit
board. (See Figure 4-9)
Hook
Figure 4-9. Panel Circuit Board Removal
Disassembly and Assembly
CPS Screws (3x4)
Tightening Torque : 6-8kgfcm
Panel Circuit Board
DISASSEMBLY AND ASSEMBLY
Panel Circuit Board
Figure 4-10. Panel Circuit Board and Function Button
Make sure that the direction of the function button is
correct.
Revision A
Function Button
38