7. Remove the two screws (CBS, M3x5) and disengage the three hooks, and
then remove the main circuit board shield plate. (See Figure 4-14)
8. Disconnect the white FFC from the main circuit board. (See Figure 4-15)
9. Disconnect the white FFC from the ferrite core. (See Figure 4-15)
10. Disconnect the white FFC from the carriage unit. (See Figure 4-16)
Main Circuit Board
Shield Plate
CBS Screws (3x5)
Tightening Torque : 8-10kgfcm
Figure 4-14. Carriage Unit Removal (4)
The FFCs should be attached to the base frame with
double-sided tape.
Disassembly and Assembly
Main Circuit Board
Hooks
FFC
DISASSEMBLY AND ASSEMBLY
Ferrite Core
Figure 4-15. Carriage Unit Removal (5)
Carriage Unit
FFC
Figure 4-16. Carriage Unit Removal (6)