Technical support maintenance manual
Note
If dose programming exceeds the maximum al-
lowed quantity (220 cc), dispensing is interrupted
automatically, the selected button flashes and the
last value set is maintained in the memory.
If a power cut should occur during the procedure,
the programming process will not be successful
and the last set dose remains saved.
7.2. RESETTING TO FACTORY DEFAULT
DOSE
To reset the machine to the pre-set factory default
doses:
- disconnect the plug from the mains outlet;
- press and hold in the dispensing buttons for about 10
seconds and simultaneously plug the power cord into
the mains outlet;
- the LEDs of the two buttons will flash alternately for
about 3 seconds.
The reset has been carried out.

8. ROUTINE MAINTENANCE

8.1. DESCALING

The formation of limestone is a normal consequence
of use of the appliance. Therefore, the machine needs
to be descaled every 2 months of use and/or when you
note irregular dispensing.
To perform descaling, you must:
a) check that there are no capsules inside the loading
compartment;
b) if present, remove the softener filter from the tank;
c) extract the drip tray / used capsule drawer, empty it
and re-insert it in the machine;
d) place a large container underneath the dispensing
spout;
e) empty the tank and fill it with a solution consisting
of the descaling product and water, as indicated on
the package of the descaling product;
f)
press the FREE DOSE button and dispense 2 cups
(about 150 ml each);
g) leave the descaling product to act for about 15-20
minutes;
h) press one of the two buttons and carry out the op-
erations described in points (f) and (g);
Rel. 0.00 / June 2018
i)
repeat the procedure in point (h) until the tank is
completely empty;
j)
remove the tank, rinse it, fill it entirely and reposition
it on the machine;
k) place a large container under the dispenser spout;
l)
select the FREE DOSE button and dispense the en-
tire content of the tank in order to rinse the circuit;
m) refill the tank and repeat the operations described in
point (l).
At the end, the descaling cycle is finished.
Note
To descale the machine, use a non-toxic, non-harm-
ful descaling product for coffee machines, guaran-
teed in compliance with standards in force and eas-
ily found on the market.
Attention
Do not descale the machine with vinegar.

8.2. CLEANING

Attention
Before cleaning the machine, make sure it is un-
plugged and wait for it to cool off.
For correct and long-lasting use of the machine, it is
recommended to:
- rinse the tank daily and fill it with cold drinking water;
- empty and clean the drip tray/used capsules container
every 2/3 days or when it is full;
- clean the dispenser spout weekly, dispensing water a
few times without inserting the capsule;
- every 3 months, clean the dispensing unit by remov-
ing it from the machine and disassembling the two
spouts that make it up in order to wash them with cold
or warm water;
- unless there are specific indications, clean the exter-
nal components of the machine (except for the elec-
tric components) using non-abrasive cloths/sponges
soaked in cold/lukewarm water.
Warning
When the machine is used intensively, perform the
cleaning operations more frequently.
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents