D
Warning
Take note of the positioning of the wirings before disconnecting them.
13.3. REMOVING THE FLOWMETER
A
B
22
1
Technical support maintenance manual
Figure D: disconnect the electri-
cal wires.
E
Then remove the solenoid valve.
Figure A: remove the electrical
connector.
Figure B: release the dosing unit
from its seat, slightly bending the
pump connection hose (1) and si-
multaneously pushing the dosing
unit itself outward.
Disconnect the two hydraulic con-
nections.
Rel. 0.00 / June 2018