Midea MTB1T-96CWN1 Technical & Service Manual page 43

R410a t3 50hz split type top-discharge series
Table of Contents

Advertisement

MCAC-UTSM-201707
Notes:
#. Connection piping diameter of outdoor unit is the stop valve diameter of the outdoor unit. When the
length of the refrigerant pipe between indoor and outdoor is not more than 30m, please connect the
straight pipe as the accessory in outdoor unit with high pressure stop valve to change the diameter of
liquid pipe to Ф9.52. When the length of the refrigerant pipe is more than 30m and less than 50m,
please connect the straight pipe (prepared in site) with low pressure stop valve to change the diameter
of gas pipe to Ф28.1.
1. The noise is measured in the semi noise suppression lab.
Midea R410A T3 50Hz Top-discharge Series
42